摘要
本文介绍了某上汽660 MW机组1号高压调门阀杆断裂异常问题,对断裂阀杆进行了化学成分分析、显微组织分析、力学性能分析和断口扫描电镜分析,并结合高压调门的结构特点和阀杆断裂面的形貌宏观特征,分析了阀杆断裂的原因,并采取了相应的措施,并举一反三进行了排查整改,消除了安全隐患,对今后避免此类问题具有指导作用。
an saic was introduced in this article 1 of 660 MW high pressure gate valve rod breaking abnormal problem,on the fracture of the valve stem chemical composition analysis,microstructure analysis,mechanical property analysis,and fracture scanning electron microscopy analysis,and combined with the structure characteristics of the high-pressure tone and stem fracture morphology of the macroscopic characteristics,analyzed the failure of the valve stem,and take the corresponding measures,and checking over the lines,to eliminate the safety hidden trouble,but also provide significant guidance to avoid such problems in the future.