本文中作者详细介绍了GB 1094.2-2013液浸式变压器温升试验绕组外推法计算电源切断瞬间的绕组温度的数学方法推导过程,并根据其计算原理提出了一种通过软件计算相关参数的方法和变压器绕组温度测量值的修正建议。
This paper introduces in detail the mathematical derivation process of calculating the winding temperature at the moment of power supply cut-off by winding extrapolation method of GB 1094.2-2013 liquid immersion transformer temperature rise test.Based on its calculation principle,a method for calculating related parameters by software and a correction suggestion for the measured value of the transformer winding temperature are proposed.
作者
张敏
王博
王伟
李鑫
董永星
郎丰源
ZHANG Min;WANG Bo;WANG Wei;LI Xin;DONG Yong-xing;LANG Feng-yuan(Xi'an High Voltage Apparatus Research Institute Co.,Ltd.,Xi'an 710077,China)
出处
《变压器》
2022年第2期33-37,共5页
Transformer
关键词
液浸式变压器
温升试验
绕组温度
外推法
liquid immersed transformer
temperature rise test
winding temperature
extrapolation method