摘要 采用溶胶-凝胶法化学合成了炭气凝胶(Carbon aerogel,CA),在此基础上采用盐酸羟胺还原法制备了炭气凝胶-纳米金纳米复合材料(Carbon aerogels-gold nanoparticles nanocomposites,CA-Au),并制备了Cs/Hb/CA-Au/GCE,对H;O;进行定量分析。结果显示,CA-Au具有良好的导电性和生物相容性,H;O;浓度与峰电流差△Ip在2~1800 μmol/L范围内呈线性关系,Y=0.0596X+0.1268(Y代表峰电流差,X代表H;O;浓度),R;=0.9993,检出限为0.783 μmol/L(S/N=3),加标回收率为97.89%~105.36%,精密度较高。且Cs/Hb/CA-Au/GCE稳定性较好,14 d后,峰电流仍可达到89.08%。Cs/Hb/CA-Au/GCE传感器制作简单、操作便捷,为过氧化氢的检测提供了一种新的方案。 Carbon aerogels(CA) were synthesized by sol-gel method,carbon aerogel-gold nanocomposites(CA-Au) were prepared by hydroxylamine hydrochloride reduction method based on CA,and Cs/Hb/CA-Au/GCE sensors were prepared for the quantitative analysis of H;O;.The results show that CA-Au has a good conductivity and biocompatibility.There was a good linear relationship between the concentration of H;O;and peak current difference △Ip in the range of 2~1800 μmol/L,Y=0.0596X+0.1268 (Y stand for peak current difference,X stand for H;O;concentration) R;=0.9993,the detection limit was 0.783 μmol/L (S/N=3),the detection limit was low and the sensitivity was high.The recoveries ranged from 97.89% to 105.36% and the precision was high.And Cs/Hb/CA-Au/GCE has good stability,after 14 days,the peak current can still reach 89.08%.The Cs/Hb/CA-Au/GCE sensor was simple to be made and easy to be operated,which provides a new scheme for the detection of hydrogen peroxide.
作者 张丽媛 ZHANG Liyuan(Department of Food and Drug Engineering,Shijiazhuang University of Applied Technology,Shijiazhuang 050081,China)
出处 《食品科技》 CAS 北大核心 2021年第11期274-279,共6页 Food Science and Technology
基金 河北省科技攻关计划项目(172102110216)。
关键词 炭气凝胶 血红蛋白 传感器 过氧化氢 检测 carbon aerogel hemoglobin sensor hydrogen peroxide detection
  • 相关文献

参考文献9

二级参考文献37

  • 1李来丙.试剂级过氧化氢中痕量阴离子的测定[J].化学试剂,2004,26(5):287-288. 被引量:1
  • 2Topoglidis E,Cass A E G,O’Regan B,et al.Immobilisation and bioelectrochemistry of proteins on nanoporous TiO2 and ZnO films[].Journal of Electrocardiology.2001 被引量:1
  • 3Luo H X,Shi Z J,Li N Q,et al.Investigation of the Electrochemical and Electrocatalytic Behavior of Single-Wall Carbon Nanotube Film On a Glassy Carbon Electrode[].Analytical Biochemistry.2001 被引量:1
  • 4Kamin R A,Wilson G S.Rotating ring-disk enzyme electrode for biocatalysis kinetic studies and characterization of the immobilized enzyme layer[].Analytical Biochemistry.1980 被引量:1
  • 5Zhao L Y,Liu H Y,Hu N F.Electroactive films of heme pro-tein-coated multiwalled carbon nanotubes[].Journal of Colloid and Interface Science.2006 被引量:1
  • 6Liu SQ,Dai ZH,Chen HY,Ju HX.Immobilization of hemoglobin on zirconium dioxide nanoparticles for preparation of a novel hydrogen peroxide biosensor[].Biosensors and Bioelectronics.2004 被引量:1
  • 7Han Nim Choi,Min Ah Kim and Won-Yong Lee.Amperometric glucose biosensor based on solel-derived metal oxide/Nafion composite films[].Analytica Chimica Acta.2005 被引量:1
  • 8Karyakin A A,Karyakina E E,Gorton L.Amperometric Biosensor for Glutamate Using Prussian Blue-Based "Artificial Peroxidase" as a Transducer for Hydrogen Peroxide[].Analytical Biochemistry.2000 被引量:1
  • 9Zhao G,Feng J J,Xu J J,et al.Direct electrochemistry and electrocatalysis of heme proteins immobilized on self-assembled ZrO2film[].Electrochemistry Communications.2005 被引量:1
  • 10Shan D,Wang SX,Xue HG,et al.Direct electrochemistry and electrocatalysis of hemoglobin entrapped in composite matrix based on chitosan and CaCO3 nanoparticles[].Electrochemistry.2007 被引量:1