期刊文献+

列车供电系统漏电流检测误报警原因分析及解决方法 被引量:4

Cause analysis and solution of false alarm in leakage current detection of train power supply system
下载PDF
导出
摘要 列车供电系统结构复杂,拖车漏电流误报警问题一直困扰着各研发单位和运用部门。文章针对一起典型的拖车漏电流误报警故障,从列车供电原理出发,分析了产生漏电流误报警的原因,并提出了解决办法,为160 km/h动力集中动车组的稳定运行提供保障。 The structure of train power supply system is complex,and the false alarm problem of leakage current for passenger car puzzles R&D unit and application departments.Based on the principle of train power supply,this paper analyzes the false alarm cause of leakage current in a typical passenger car.The solution is put forward to ensure the stable operation for 160 km/h power concentrated EMU.
作者 胡亮 陈湘 李顺 蔡杰 HU Liang;CHEN Xiang;LI Shun;CAI Jie(CRRC Zhuzhou Locomotive Co.,Ltd.;Zhuzhou CRRC Times Electric Co.,Ltd.,Zhuzhou 412001,China)
出处 《电力机车与城轨车辆》 2021年第3期60-63,共4页 Electric Locomotives & Mass Transit Vehicles
关键词 动力集中动车组 列车供电系统 漏电流 电流传感器 power centralized EMU train power supply system leakage current current sensor