期刊文献+

磁共振TSE-DWI序列表观扩散系数对急性脊髓损伤的诊断价值 被引量:2

Diagnostic Value of Apparent Diffusion Coefficient of TSE-DWI Sequence in Acute Spinal Cord Injury
下载PDF
导出
摘要 本文探讨磁共振TSE-DWI序列表观扩散系数(ADC)在急性脊髓损伤诊断中的价值。选取68例急性脊髓损伤患者作为观察组,其中轻中度损伤40例、重度损伤28例,同时选取体检健康者50例作为对照组,均给予TSE-DWI序列扫描。观察组与对照组比较,病变部位ADC值明显低于正常部位(P<0.05)。观察组重度损伤患者病变部位ADC值明显低于轻中度患者病变部位(P<0.05)。观察组治疗后病变部位ADC值较治疗前有所升高(P<0.05)。以ADC值判断重度损伤的灵敏性和特异性较高。磁共振TSE-DWI序列ADC值有助于判断急性脊髓损伤严重程度。 The value of apparent diffusion coefficient(ADC)of TSE-DWI in the diagnosis of acute spinal cord injury was discussed.A total of 68 patients with acute spinal cord injury were selected as the observation group,including 40 cases of mild to moderate injury and 28 cases of severe injury.Fifty cases of healthy physical examination were selected as control group.All of them were given TSE-DWI sequence scanning.The ADC value of the lesion site in the observation group was significantly lower than that in the control group(P<0.05).The ADC value of the lesion site in the observation group was significantly lower than that in mild to moderate patients(P<0.05).The ADC value of the lesion site in the observation group was higher than that before treatment(P<0.05).The sensitivity and specificity of ADC value to judge the severity of injury were high.The ADC value of TSE-DWI sequence is helpful to judge the severity of acute spinal cord injury.
作者 曹在民 郝占元 冯琳 CAO Zaimin;HAO Zhanyuan;FENG Lin(North China Medical&Health Group Xingtai General Hospital,Xingtai 054000,Hebei,P.R.China)
出处 《影像科学与光化学》 CAS 北大核心 2021年第3期460-463,共4页 Imaging Science and Photochemistry
基金 2020年邢台市市级科技计划自筹经费项目(2020ZC191)。
关键词 磁共振 TSE-DWI序列 表观扩散系数 急性脊髓损伤 MRI TSE-DWI sequence apparent diffusion coefficient acute spinal cord injury
  • 相关文献

参考文献8

二级参考文献43

  • 1王霄英,谭可,倪石磊,孙非,鲍圣德,蒋学祥.MRI和DTI评价犬急性脊髓损伤后的形态及功能改变[J].中国医学影像技术,2004,20(12):1821-1824. 被引量:15
  • 2Clark CA, Barker GJ, Tofts PS. Magnetic resonance diffusion imaging of the human cervical spinal cord in vivo. Magn Reson Med, 1999, 41:1269. 被引量:1
  • 3Hajnal JV, Doran M, Hall AS, et al. MR imaging of anisotropically restricted diffusion of water in the nervous system: Technical, anatomic and pathologic considerations. J Comput Assist Tomogr, 1991, 15:1. 被引量:1
  • 4Green HA, Pena A, Price CJ, et al. Increased anisotropy in acute stroke: A possible explanation. Stroke, 2002, 33:1517. 被引量:1
  • 5Sener RN. Atypical X-linked adrenoleukodystrophy: New MRI observations with FLAIR, magnetization transfer contrast, diffusion MRI, and proton spectroscopy. Magn Reson Imaging, 2002, 20:215. 被引量:1
  • 6Lam WW, Poon WS, Metreweli C. Diffusion MR imaging in glioma:Does it have any role in the pre-operation determination of grading of glioma? Clin Radiol, 2002, 57:219. 被引量:1
  • 7Fiebach JB, Jansen O, Schellinger PD, et al. Serial analysis of the apparent diffusion coefficient time course in human stroke. Neuroradiology, 2002, 44:294. 被引量:1
  • 8Schocke MF, Seppi K, Esterhammer R, et al. Diffusion-weighted MRI differentiates the Parkinsion variant of multiple system atrophy from PD.Neurology, 2002, 58 : 575. 被引量:1
  • 9Holder CA, Muthupillai R, Mukundan S Jr, et al. Diffusion-weighted MR imaging of the normal human spinal cord in vivo. AJNR, 2000, 21 :1799. 被引量:1
  • 10Holder CA. MR diffusion imaging of the cervical spine. Magn Reson Imaging Clin N Am, 2000, 8:675. 被引量:1

共引文献59

同被引文献10

引证文献2

二级引证文献3