期刊文献+

200MW机组低压缸微进汽供热改造案例分析 被引量:1

Analysis of Low Pressure Cylinder with Small Steam Intake for Heating Supply Improvement in a 200MW Unit
下载PDF
导出
摘要 文章以某发电公司200MW机组为例,并结合电厂外界发电负荷和热负荷现状,提出采用低压缸微进汽改造技术进行改造。改造后,新增供热能力明显提升,能够满足外界电热负荷的需求。 Taking power generation company with 200MW unit as the example,this paper applies a heating supply improvement by low pressure cylinder with small steam intake based on the existing power and heating loads.It is found that the heating capacity have been greatly improved to meet the heating requirements under the power and heating loads.
作者 李成磊 郑立军 高新勇 Li Chenglei;Zheng Lijun;Gao Xinyong(Huadian Electric Power Research Institute Co.,Ltd.,Hangzhou Zhejiang 310030)
出处 《工程技术研究》 2020年第22期95-96,共2页 Engineering and Technological Research
关键词 低压缸微进汽 供热改造 经济性 low pressure cylinder with small steam intake heating supply improvement economy