期刊文献+

矿用带式输送机拉线急停开关故障及处理 被引量:3

Fault of Emergency Switch of Belt Conveyor Pull Line and Treatment
下载PDF
导出
摘要 针对方山店坪煤矿2041巷掘进期间SSJ-100型带式输送机拉线急停开关在出现跑偏、打滑、撕带时不能及时对输送机断电问题,主要分析了拉线急停开关的工作原理及常见故障,并提出了相应的解决措施.通过实际应用效果来看,取得了显著应用成效. Aiming at the common faults of SSJ-100 type belt conveyor pull line stop switch during the excavation of 2041 roadway in Fangshan Dianping Coal Mine, which causes the belt conveyor to appear the deviation, the slip, the tear belt time does not start,the paper mainly analyzes the working principle and common faults of the cable stop switch, and puts forward the corresponding countermeasures. Through the practical application effect, remarkable application effect has been obtained.
作者 张晋锋 Zhang Jinfeng(Fangshan Dianping Coal Mine,Shanxi Lyuliangshan Coal Power Co.,Ltd.,Lyuliang Shanxi 033102)
出处 《机械管理开发》 2020年第11期319-320,共2页 Mechanical Management and Development
关键词 带式输送机 拉线急停开关 故障分析 处理措施 belt conveyor cable stop switch fault analysis treatment measures