期刊文献+

地埋引线蓄电池开发与应用 被引量:3

Development and application of lead-acid battery with buried lead
下载PDF
导出
摘要 传统蓄电池若埋于地下,容易产生进水、端柱腐蚀、充电过程产生的气体无法排出等问题,严重影响电池的使用寿命。本文介绍了一种具有一体化模块式设计、全密封式结构和高效集中排气系统的地埋引线蓄电池产品。这种蓄电池具有良好的防水性能、耐腐蚀性能、散热性能和排气性能,高可靠性,较长的使用寿命。 If the traditional storage battery is buried in the ground,it is easy to produce water inflow,terminal post corrosion,and the gas produced in the operation will not be discharged,resulting in safety risks and other problems,which seriously affect the service life of the battery.This paper discusses the development and application of the buried lead battery products,the integrated modular design,the fully sealed structure,with good waterproof and corrosion resistance performance,and the new design is highly efficient.The middle exhaust system has excellent heat dissipation performance,good exhaust performance and high reliability,effectively extending the service life of the battery.
作者 苗壮 刘立志 王金生 孔德龙 MIAO Zhuang;LIU Lizhi;WANG Jinsheng;KONG Delong(Shandong Sacred Sun Power Sources Co.,Ltd.,Qufu Shandong 273100;Jining Polytechnic,Jining Shandong 272000,China)
出处 《蓄电池》 2020年第5期247-250,共4页 Chinese LABAT Man
关键词 地埋 引线 一体化 模块式 蓄电池 端柱 腐蚀 集中排气 buried lead integrated modular battery terminal post corrosion middle exhaust
  • 相关文献