摘要
论述了室外一体化电源系统的发展现状以及存在的问题。前端接入式胶体蓄电池的开发,在满足标准一体化电源系统对蓄电池的外形、安装、维护要求的前提下,优化结构设计,提高了蓄电池的耐高温能力、充电接受能力、过放电能力等,很好地解决了电信级前置端子阀控铅酸蓄电池在室外一体化电源系统中存在的不足。
The development status and problems of outdoor integration power system are discussed. The structure design of front-connected gelled VRLA batteries is optimized on the premise of satisfying the requirements of standard integration power supply system for shape, installation, maintenance of VRLA batteries, in order to improve the high-temperature performance, charge acceptance ability, over-discharge capability and so on. Therefore, the deficiencies of the front terminal VRLA batteries used in the outdoor integration power supply system in the field of telecommunication are solved.
出处
《蓄电池》
2012年第3期107-111,共5页
Chinese LABAT Man
关键词
室外一体化电源
前端接入式
胶体蓄电池
前置端子蓄电池
outdoor integration power supply
front-connected type
gelled battery
front terminal VRLAbattery