摘要
介绍了某公司电脱盐切水结垢原因分析及其影响,并对缓解换热器结垢方法进行筛选。结果表明,进行工艺流程优化,以最少投资将换热器结垢问题得到了有效控制。
This paper introduced the cause analysis and influence of fouling of water-draining of electric desalination,and screened the methods of reducing heat exchanger fouling. The results showed that the fouling problem of heat exchanger can be effectively controlled with minimum investment after process optimization.
作者
蔡帮伟
侯利国
杨威
杨洪凯
边绪亮
Cai Bangwei;Hou Liguo;Yang Wei;Yang Hongkai;Bian Xuliang(No.1 department of Refinery,CNOOC Huizhou Petrochemical Co.Ltd,Huizhou 516086,China)
出处
《炼油与化工》
2020年第4期36-38,共3页
Refining And Chemical Industry
关键词
电脱盐切水
老化油
结垢
流程优化
electro-desalting water-draining
aged oil
fouling
process optimization