摘要
介绍了自动加药装置在数据机房空调循环冷却水系统水质管控中的应用。通过对金属腐蚀率以及电导率趋势进行分析,评估水质管控措施对数据中心冷水机组运行能耗、运行安全以及节约用水方面的作用。
This paper introduces the application of automatic dosing device in the water quality control of air conditioning circulating cooling water system in data center. Based on the analysis of metal corrosion rate and conductivity trend, the paper gives an the evaluation of the effect of on the operation energy consumption, operation safety and water saving of data center chiller with the water quality control measures.
出处
《节能》
2020年第6期100-102,共3页
Energy Conservation
关键词
数据中心
空调系统
水质管控
节约用水
data center
air condition system
water quality control
water saving