期刊文献+

剪切波弹性成像评价胎盘功能研究进展 被引量:7

Progresses of shear wave elastography in evaluation of placental function
下载PDF
导出
摘要 胎盘功能受损可导致母婴不良结局。早期诊断胎盘功能不全对预防疾病发生及改善胎儿预后有重要意义。通过定量测量胎盘弹性,剪切波弹性成像(SWE)有望成为评价和预估胎盘功能的新方法。本文对SWE评价胎盘功能研究进展进行综述。 Placental dysfunction can induce adverse outcomes of mother and fetus.Early diagnosis of placental dysfunction is of great significance for prevention of disease and improvement of fetal prognosis.Shear wave elastography(SWE)is expected to be a new method for evaluating and predicting placental function through quantitative measurement of placental elasticity.The research progresses of SWE on evaluation of placental function were reviewed in this article.
作者 高瑾 胡兵 GAO Jin;HU Bing(Department of Ultrasound,Affiliated Renhe Hospital of China Three Gorges University,Yichang 443001,China)
出处 《中国医学影像技术》 CSCD 北大核心 2020年第5期780-783,共4页 Chinese Journal of Medical Imaging Technology
基金 宜昌市科学技术局项目(A19-301-35)。
关键词 胎盘 弹性成像技术 超声检查 placenta elasticity imaging techniques ultrasonography
  • 相关文献

参考文献12

二级参考文献152

  • 1李俊来,黄炎,王知力,万文博,苏莉,唐杰.乳腺实时剪切波弹性成像的组织定征研究[J].中华医学超声杂志(电子版),2011,8(4):812-819. 被引量:68
  • 2郑剑,曾婕,郑荣琴,黄泽萍,任杰,王丛知,郑海荣.检测深度对肝脏实时剪切波弹性成像的影响[J].中华医学超声杂志(电子版),2013,10(8):647-651. 被引量:20
  • 3Bercoff J,Tanter M,Fink M. Supersonic shear imaging:a new technique for soft tissue elasticity mapping[J].{H}IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control,2004,(04):396-409. 被引量:1
  • 4Bavu E,Gennisson JL,Couade M. Noninvasive in vivo liver fibrosis evaluation using supersonic shear imaging:a clinical study on 113 hepatitis C virus patients[J].{H}Ultrasound in Medicine & Biology,2011,(09):1361-1373. 被引量:1
  • 5Ferraioli G,Tinelli C,Bello BD. Accuracy of real-time shear wave elastography for assessing liver fibrosis in chronic hepatitis C:A pilot study[J].{H}HEPATOLOGY,2012,(06):2125-2133. 被引量:1
  • 6Poynard T,Munteanu M,Luckina E. Liver fibrosis evaluation using real-time shear wave elastography:applicability and diagnostic performance using methods without a gold standard[J].{H}Journal of Hepatology,2013,(05):928-935. 被引量:1
  • 7Castera L,Foucher J,Bernard PH. Pitfalls of liver stiffness measurement:a 5-year prospective study of 13,369 examinations[J].{H}HEPATOLOGY,2010,(03):828-835. 被引量:1
  • 8Stebbing J,Farouk L,Panos G. A meta-analysis of transient elastography for the detection of hepatic fibrosis[J].{H}Journal of Clinical Gastroenterology,2010,(03):214-219. 被引量:1
  • 9Friedrich-Rust M,Nierhoff J,Lupsor M. Performance of acoustic radiation force impulse imaging for the staging of liver fibrosis:a pooled meta-analysis[J].{H}Journal of Viral Hepatitis,2012,(02):e212-e219. 被引量:1
  • 10Wong GL,Wong VW,Chim AM. Factors associated with unreliable liver stiffness measurement and its failure with transient elastography in the Chinese population[J].{H}Journal of Gastroenterology and Hepatology,2011,(02):300-305. 被引量:1

共引文献227

同被引文献64

引证文献7

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部