腔内心电图定位技术在中心静脉置管中的应用效果 被引量:8

Application of intracavitary electrocardiography in central vein catheterization
下载PDF
导出
摘要 目的探讨腔内心电图定位技术在中心静脉置管中的应用效果。方法前瞻性选取2019年1~6月徐州医科大学附属医院收治的中心静脉置管患者100例,按照随机数字表随机分为对照组和观察组,每组各50例。对照组患者采用中心静脉置管常规方法,观察组患者则在中心静脉置管常规方法上加用腔内心电图定位技术引导定位。比较两组患者的一次置管成功率、中心静脉导管尖端到位率。结果观察组和对照组患者的一次置管成功率分别为98.0%和92.0%,两组比较差异无统计学意义(P>0.05);观察组和对照组患者的中心静脉导管尖端到位率分别为98.0%和82.0%,观察组明显高于对照组,差异具有统计学意义(P<0.05)。结论腔内心电图定位技术可引导中心静脉置管定位,相对于常规方法更加准确有效,导管尖端到位率较高,值得在临床推广应用。 Objective To explore the application effect of intracavitary electrocardiography(intracavitary electrocardiography,IC-ECG)localization technology in central vein catheterization.Methods 100 patients with central vein catheterization admitted in the Affiliated Hospital of Xuzhou Medical University from January to June 2019 were enrolled in this prospective study and were randomly divided into two groups:the control group and the observation group,50 cases in each group.The patients in the control group used the routine method of central vein catheterization,while the patients in observation group used the IC-ECG to guide the location based on the routine method of central vein catheterization.The success rate of one-time catheterization and the in-place rate of the central venous catheter tip were compared between the two groups.Results There was no significant difference(P>0.05)in the success rate of one-time catheterization between the observation group(98.0%)and the control group(92.0%);the in-place rate of catheter tip in the observation group(98.0%)was significantly higher than that in the control group(82.0%),the difference was statistically significant(P<0.05).Conclusion Intracavitary electrocardiographic localization technology can guide the positioning of central vein catheterization,which is more accurate and effective than the routine method,and the in-place rate of catheter tip is higher,which is worthy of clinical application.
作者 徐小班 钱韦韦 李玉平 赵静 XU Xiao-ban;QIAN Wei-wei;LI Yu-ping(Department of Anesthesiology,The Affiliated Hospital of Xuzhou Medical University,Xuzhou Jiangsu 221002,China;Nursing Department,The Affiliated Hospital of Xuzhou Medical University,Xuzhou Jiangsu 221002,China;Department of Medical Records Statistics,The Affiliated Hospital of Xuzhou Medical University,Xuzhou Jiangsu 221002,China)
出处 《临床和实验医学杂志》 2020年第10期1117-1119,共3页 Journal of Clinical and Experimental Medicine
基金 江苏省高校自然科学研究面上项目(编号:17KJB320023) 徐州市科技项目(编号:KC18056、KC17174)。
关键词 中心静脉导管 腔内心电图 定位 Central venous catheter Intracavitary electrocardiography Location
  • 相关文献

参考文献4

二级参考文献58

  • 1莫平,卢振和,何荣芝,郑志远,钱耀亮,赵雾红.中心静脉导管位置与新型静脉内心电图[J].临床麻醉学杂志,2007,23(7):569-571. 被引量:14
  • 2Vesely TM.Central venous catheter tip position:a continuing controversy [J]. J Vasc Interv RadioI,2003,14(5):527-534. 被引量:1
  • 3Racadio JM,Doellman DA,Johnson ND,et al.Pediatfic peripherally inserted central catheters:complication rates related to catheter tip location[J]. Pediatrics,2001,107(2) :E28. 被引量:1
  • 4Kearns PJ,Coleman S,Wehner JH.Complications of long arm-catheters:a randomized trial of central vs peripheral tip loeatian[JJ. J Parenter Enteral Nutr. 1996,20 ( 1 ) : 20-24. 被引量:1
  • 5Frey AM. Pediatric peripherally inserted centra/ catheter program report:a summary of 4,536 catheter daysEJ]. J lntraven Nuts,1995,18 (6):280-291. 被引量:1
  • 6Gamulka B,Mendoza C,Connolly B.Evaluation of a unique,aurse-insert- ed,peripheraUy inserted central catheter program[J]. Pediatrics,2005,1 t5 (6) : 1602-1606. 被引量:1
  • 7Ohki Y,Tabata M,Kuwashima M,et al. Ultrasonographic detection of very thin pcrcutaneous central venous catheter in neonates[J]. Acta Pacdiatr, 2000,89 ( 11 ) : 1381 - 1384. 被引量:1
  • 8Hellerstein HK,Pritchard WH,Lewis RL.Recording of intracavity po- tentials through a single lumen,saline fired cardiac catheter[J]. Proc Soc Exp Biol Med, 1949,71 ( 1 ) :58-60. 被引量:1
  • 9John SD,Sw/schuk LE. Chest[M]//Swischuk LE,John SD ed. Differen- tim diagnosis in pediatric radiology.2nd ed. Bahimore:WiUiams & Wilkins, 1995 : 85-105. 被引量:1
  • 10Silverman NH.Interatrial communications[M]//Silverman NH ed. Pe- diatric echocardiography. Baltimore:Williams & Wi|kins, 1993 : 109-121. 被引量:1

共引文献195

同被引文献71

引证文献8

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部