期刊文献+

QT500-7球墨铸铁拉伸试样断口异常分析 被引量:1

Abnormal Analysis on Fracture of QT500-7 Ductile Iron Tensile Specimen
下载PDF
导出
摘要 拉伸试验中QT500-7球墨铸铁拉伸试样断裂后断口存在颜色较深的异常区。通过宏观观察、化学成分分析、金相检验、力学性能测试等方法对异常区形成原因进行了分析。结果表明:球墨铸铁铸造过程中局部石墨球化不良或球化衰退造成了该区域显微组织中有大量的蠕虫状石墨,导致球墨铸铁拉伸试样断口异常,这严重降低了球墨铸铁材料的屈服强度、抗拉强度和断后伸长率等力学性能。 In the tensile test,the fracture surface of QT500-7 ductile iron tensile specimen had dark abnormal area on the fractured specimen.The causes of the abnormal area were analyzed by means of macroscopic observation,chemical composition analysis,metallographic examination and mechanical property test.The results show that there were a lot of vermicular graphite in the microstructure of ductile iron caused by the poor spheroidization or the degradation of spheroidization during the casting process,which led to the abnormal fracture of ductile iron tensile specimen,which seriously reduced the mechanical properties of ductile iron such as yield strength,tensile strength and elongation after fracture.
作者 方元 FANG Yuan(Wuhu Bethel Automobile Safety System Co.,Ltd.,Wuhu 241000,China)
出处 《理化检验(物理分册)》 CAS 2020年第3期36-38,60,共4页 Physical Testing and Chemical Analysis(Part A:Physical Testing)
关键词 球墨铸铁 蠕虫状石墨 球化不良 力学性能 ductile iron vermicular graphite poor spheroidization mechanical property
  • 相关文献

参考文献7

二级参考文献44

共引文献59

同被引文献10

引证文献1

二级引证文献1

相关作者