摘要
本文分析了一种高炮火控电站信息化设计中所面对的困难因素,介绍了解决困难的各种改进措施,通过精细化设计,使电站的各项指标达到信息化改进技术要求的规定。经试验证明,信息化改进设计达到要求。
This paper analyzes the diffcult factors in the informatization design of an anti-aircraft gun fire con-trol power station,and introduces various improvement measures to solve the difficulties.Through the refined design,the indexes of the power station can meet the requirements of the informatization improvement technology.The test shows that the improved design of informatization meets the requirements.
作者
闵道广
张祖淼
范礼辉
王利泉
MIN Dao-guang;ZHANG Zu-miao;FAN Li-hui;WANG Li-quan(Tellhow Technology Co.,Ltd,JiangXi Nanchang 330096;China telecom co.,LTD.,gansu branch,GanSu Lanzhou 730050)
出处
《移动电源与车辆》
2019年第4期15-18,26,共5页
Movable Power Station & Vehicle
关键词
移动电站
信息化改进
低温适应性
高温适应性
高原适应性
mobile power station informatization
low temperature adaptability
high temperature adaptabilty
plateau adaptablity