在鼓泡反应装置中进行了MgO为吸收区吸收剂、NaClO2为氧化区吸收剂的脱硫脱硝实验,研究了NaClO2浓度、NaClO2溶液的pH、温度和烟气体积流量等参数对脱硫脱硝效率的影响,并在液相产物分析的基础上推测了反应历程。结果表明:在最佳条件下,SO2和NO的脱除效率均达到100%,NOx的脱除效率可达65%。
Based on separated layout of different absorbents,an experimental study was carried out in two bubbling reactors on the simultaneous desulfurization and denitrification with MgO and NaClO2 as the absorbents respectively for the absorption region and oxidizing region,so as to analyze the effects of following factors on the desulfurization and denitrification efficiency,such as the concentration and initial pH value of NaClO2 solution,the reaction temperature and the flue gas flow rate,etc.In addition,the reaction mechanism was deduced based on an analysis of the liquid products.Results show that the removal efficiency of both SO2 and NO could reach 100%,under optimal experimental conditions,while the removal rate of NOx could achieve 65%.
作者
刘凤
李昊天
张彩端
张晓光
汪黎东
刘鹏宾
曾芳
LIU Feng;LI Haotian;ZHANG Caiduan;ZHANG Xiaoguang;WANG Lidong;LIU Pengbin;ZENG Fang(Key Laboratory of Regional Energy System Optimization,Ministry of Education,North China Electric Power University,Beijing 102206,China;School of Environmental Science and Engineering,North China Electric Power University,Baoding 071003,Hebei Province,China;Pingdingshan China Power Environmental Protection Power Generation Co.,Ltd.,Pingdingshan 475000,Henan Province,China)
出处
《动力工程学报》
CAS
CSCD
北大核心
2019年第12期994-998,1004,共6页
Journal of Chinese Society of Power Engineering
基金
科技部国家重点研发计划资助项目(2016YFC0204102)
国家自然科学基金资助项目(51508188)
关键词
MGO
NaClO2
吸收剂分区
脱硫
脱硝
MgO
NaClO2
separated layout of absorbent
desulfurization
denitrification