辐射诱导一体化末端冬季性能特性试验研究 被引量:4

Performance Evaluation and Experimental Study of The Induction Radiant Air-Conditioning System in Winter
下载PDF
导出
摘要 提出了一种将诱导器与辐射顶板相结合的一体化空调末端形式,从而实现了辐射对流结合效果。对该末端进行试验探究,测试了不同室内设定参数对系统供暖性能和室内热环境参数的影响,并与传统空调进行比对。试验结果显示,通过采用新型末端,可在辐射以及诱导的双重作用下形成竖直方向和水平方向相对均匀的室内温度场,符合舒适性要求。 An air-conditioning system that combines the inducer and radiant ceiling panel was proposed to achieve the combined effect of radiation and convection.The indoor terminal device was investigated experimentally,the effects of different indoor set parameters on system heating performance and indoor heat environment parameters were measured,and compared with conventional air conditioning system.The test results show that relatively uniform indoor temperature field can be formed in vertical and horizontal directions under double action of radiation and induction,which meets the comfort requirements.
作者 陈新 张小松 徐国英 Chen Xin;Zhang Xiaosong;Xu Guoying(School of Energy and Environment,Southeast University,Nanjing 210096,China)
出处 《流体机械》 CSCD 北大核心 2019年第10期55-59,共5页 Fluid Machinery
基金 “十三五”国家重点研发计划项目(2016YFC0700303)
关键词 辐射 诱导送风 空调系统 radiation induced ventilation air conditioning system
  • 相关文献

参考文献7

二级参考文献40

  • 1郑树伟,丘林,王文海.调湿建材应用于辐射供冷房间的可行性[J].制冷与空调,2004,4(4):70-73. 被引量:11
  • 2李常河,李永安,刘学来,张晓锋.地板辐射供冷系统地面温度的确定[J].低温建筑技术,2005,27(2):94-95. 被引量:11
  • 3李先中,刘传聚,王子介.置换通风对地板供冷的影响[J].制冷与空调,2004,4(1):48-50. 被引量:5
  • 4朱冬生,沈家龙,唐广栋,蒋翔,欧阳惕.水分布对蒸发式冷凝器传热传质的影响[J].工程热物理学报,2007,28(1):83-85. 被引量:27
  • 5Feustel H E, Stetiu C. Hydronic radiant cooling-preliminary assessment[J]. Energy and Buildings, 1995, 22(3) : 193- 205. 被引量:1
  • 6Loveday D L, Parsons K C, Taki A H. Displacement ventila- tion environments with chilled ceilings: thermal comfort de- sign within the context of the BS EN ISO7730 versus adaptive debate[J]. Energy and Buildings, 2002, 34(6): 573-579. 被引量:1
  • 7Ashfaque A C, Rasul M G, Khan M M K. Thermal-comfort analysis and simulation for various low-energy cooling-techn- ologies applied to an office building in a subtropical climate [J]. Applied Energy, 2008, 85(6): 449-462. 被引量:1
  • 8Kim T, Kato S, Murakami S. Indoor cooling/heating load analysis based on coupled simulation of convection, radiation and HVAC control[J]. Building and Environment, 2001, 36 (7) : 901-908. 被引量:1
  • 9Olesen B W, Michel E, Bonnefoi F, et al. Heat exchange coefficient between floor surface and space by floor cooling- theory or a question of definition[J]. ASHRAE Transactions, 2000, 106(1): 684-694. 被引量:1
  • 10李先中 王子介.地板供冷—置换通风复合系统在住宅建筑中的应用[J].电气与智能建筑,2002,(11):62-65. 被引量:2

共引文献93

同被引文献32

引证文献4

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部