摘要
用反相高效液相色谱法测定了人血浆中的辅酶Q10,样品用正己烷萃取 ,甲醇 -乙醇 (体积比70∶30,含20mmol/LLiClO4)为流动相 ,在WatersμBondapakC18 柱上分离并于波长275nm下检测 ,外标法定量 ;方法线性范围为10~100ng,r=0.9998,平均回收率为96 % ,相对标准偏差为3.0 % ;方法检出限为2ng(质量 )和0.2mg/L(质量浓度 )。
Reverse - phase high - performance liquid chromatography with UV detector was investigated as a method for the assay of coenzyme Q10 in human plasma. After deproteinization sample was extracted by n - hexane. Separation was performed in a Waters μBondapak C18 column at 25 ℃ by using an eluent of methanol-ethanol(70∶30 by volume, including 20 mmol/L LiClO4) with flow rate of 1.0 mL/min, the eluate was monitored by UV detector at 275 nm. Coenzyme Q10 was quantitatively determined by an external standard method. Detection limit of 2 ng and 0.2 mg/L were achieved. A linear range of 10~100 ng, correlation coefficient of 0.999 8, RSD of 3.0%, and average recovery of 96%, were obtained for the method.
出处
《分析测试学报》
CAS
CSCD
北大核心
2002年第6期89-91,共3页
Journal of Instrumental Analysis