摘要
深圳市横岗污水处理厂一期采用上向流反硝化深床滤池模块化标准件进行提标改造。该工程从设计至调试运行共2个月,出水水质已达到《地表水环境质量标准》(GB 3838—2002)的准Ⅳ类标准,且达到设计产水规模10×10^4m^3/d。实践表明,上向流反硝化深床滤池标准件特别适用于建设工期紧的提标改造工程。同时,该项目的成功应用为大型污水处理厂采用模块化标准件现场装配的建设方式提供了经验。
The modular standardized equipments of upflow denitrification deep bed filter were used for the phase Ⅰ upgrading project of Shenzhen Henggang wastewater treatment plant( WWTP). The effluent quality of the project reached quasi-Ⅳ level standard of Environmental Quality Standard for Surface Water( GB 3838-2002) at the designed water production capacity of 10 × 10^4 m^3/d after commissioning for two months. The results showed that the upflow denitrification deep bed filter standardized equipment were especially suitable for the renovation projects with short construction period.At the same time, the successful application of the project provided valuable experience for the construction of modular water treatment equipment in large-scale WWTPs.
作者
伍波
叶昌明
WU Bo;YE Chang-ming(Shenzhen Qingquan Water Industry Co. Ltd.,Shenzhen 518116 ,China)
出处
《中国给水排水》
CAS
CSCD
北大核心
2019年第18期99-101,共3页
China Water & Wastewater
关键词
污水处理厂
提标改造
模块化水处理装备
反硝化深床滤池
wastewater treatment plant
upgrading and reconstruction
modular water treatment equipment
denitrification deep bed filter