期刊文献+

顶空气相色谱-电子捕获检测器法测定牛肺表面提取物质中三氯甲烷的残留量

Determination of residual trichloromethane in calf pulmonary surfactant extracts by Headspace GC-ECD
原文传递
导出
摘要 目的测定牛肺表面提取物质中三氯甲烷的残留量。方法采用顶空进样毛细管气相色谱法,色谱柱为DB-624毛细管柱,载气为氮气,用ECD检测器测定牛肺表面提取物质中的三氯甲烷残留量(外标法计算)。结果分离度符合要求,质量浓度在考察范围内与峰面积的线性关系良好,r=0. 9999,平均回收率为99. 56%~100. 75%,精密度的RSD值为1. 21%,定量限为6×10-3ng·m L-1。结论所用方法准确可靠,可用于样品中三氯甲烷残留量的测定。 OBJECTIVE To determine the residual trichloromethane in calf pulmonary surfactant extracts( CPSE) by Headspace GC-ECD. METHODS The residual trichloromethane was quantitatively determined by headspace GC on DB-624 column. and the detector temperature of electron capture detector( ECD) adopted external standard method. RESULTS The peaks of residual organic solvents were completely separated. There was a good linearity in the experimental concentration( r =0. 9999). The average recovery rate ranged from 99. 56% to 100. 75%. The detection limit was 6 × 10-3 ng·m L-1. RSD of precision was less than 1. 21%. CONCLUSION The method is accurate. It can be used for the determination of residual trichloromethane in CPSE.
作者 赵璇 李群 白亦昊 周长明 ZHAO Xuan;LI Qun;BAI Yihao;ZHOU Changming(Beijing Key Laboratory of Analysis and Evaluation on Chinese Medicine,NMPA Key Laboratory for Research and Evaluation of Generic Drugs,Beijing Institute for Drug Control,Beijing 102206 P.R. China)
出处 《华西药学杂志》 CAS CSCD 2019年第5期502-504,共3页 West China Journal of Pharmaceutical Sciences
关键词 顶空气相色谱法 电子捕获检测器 牛肺表面提取物质 三氯甲烷 残留量 外标法 程序升温 质量控制 Headspace GC Electronic capture detector Calf pulmonary surfactant extracts Trichloromethane Residual quantity External standard method Temperature programmed Quality control
  • 相关文献

参考文献5

二级参考文献17

共引文献57

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部