期刊文献+

民用飞机引气过热探测告警温度设计和验证 被引量:3

Design and Verification of Civil Aircraft Bleed Air Overheat Detection
下载PDF
导出
摘要 民用飞机引气过热探测系统用于探测高温引气泄漏,防止持续泄漏的高温引气对周围的结构和设备造成损坏。探测器告警温度根据探测器周围的最高环境温度设置,根据不同的探测需求,系统可以设置不同的告警温度。系统在方案设计阶段,探测器告警温度是根据理论计算的最高环境温度设置。采用试验的方法,通过测试飞机引气过热探测器的环境温度,建立新的计算方法,修正探测器的理论最高环境温度,用于验证系统告警温度设置的合理性。 The bleed air overheat detection system for civil aircraft was used to detect the leakage of bleed air duct and prevent continuous leakage of high temperature bleed air exhaust on the structure and equipment. The alarm set-point is usually set according to maximum ambient temperature around sensor. But the different alarm set-points can also be set according to the detection requirement. During the stage of system design, the alarm set-point was set according to the theoretical calculation of ambient temperature. In this paper a new calculation method is established by testing the ambient temperature and correcting the sensor’s theoretical maximum ambient temperature so as to verify the rationality of the alarm set-point.
作者 陈彦伟 CHEN Yanwei(Shanghai Aircraft Design and Research Institute,Shanghai 201210)
出处 《民用飞机设计与研究》 2019年第3期67-70,共4页 Civil Aircraft Design & Research
关键词 引气 探测 告警温度 验证 bleed air detection alarm set-point verification
  • 相关文献

参考文献8

二级参考文献27

  • 1郭茶秀,张务军,熊辉东,Rainer Tamme.共晶盐蓄冷球凝固过程的数值模拟研究[J].暖通空调,2006,36(3):17-21. 被引量:10
  • 2邵辉,施志荣,朱其良.示踪技术用于气体泄漏扩散模拟的多元线性回归分析[J].安全与环境学报,2006,6(4):112-114. 被引量:10
  • 3郭文辉,曾宪云.管道泄漏检测技术[J].工业安全与环保,2007,33(2):40-42. 被引量:19
  • 4吴望一.流体力学[M].北京:北京大学出版社,1983.. 被引量:50
  • 5E Fessler. 757 environmental control system [ J ]. TechAir, 1983, 41 (5) : 7- 10. 被引量:1
  • 6Brake Daniel E., Stearns Steven V., RonskyN. Dary. Enhanced pipeline leak detection using air- borne differential absorption LIDAR[R].Proceedings of the Biennial International Pipeline Conference, 2008, 2:941-948. 被引量:1
  • 7Wang Likun, Xu Bin, Wang Hongchao, et al. Oil pipeline leak detection system based on acoustic wave technology [J]. Applied Mechanics and Materi- als, 2012, v220-223:1628-1632. 被引量:1
  • 8Hua Ke ,Ye Hao, Wang, Guizen, et al. Study on acoustic based leak detection and localization of na- ture gas pipeline[J]. Journal of Huazhong University of Science and Technology, 2009(1 ):181 - 183. 被引量:1
  • 9Chilekwa Victor, Sharp David. Detection, location and sizing of multiple leaks in a duct[R]. Forum Acusticum Budapest 2005: 4th European Congress on Acustics, 2005:2569-2572. 被引量:1
  • 10Leslie Fernandes, Arnaud Amy. Bleed Leak De- tection system [P]. America, United States Patent, US7155961B2, 2007. 被引量:1