Experimental Study on Performance of a Closed Wet Cooling Tower for Air Wet-Bulb Temperature near 0°C 被引量:2

Experimental Study on Performance of a Closed Wet Cooling Tower for Air Wet-Bulb Temperature near 0°C
原文传递
导出
摘要 Closed wet cooling towers(CWCTs) are used widely because of their better water quality and smaller water consumption. However, the operating parameters shown in the technical documents are only for rated conditions in summer, not for any other conditions, especially in low air wet-bulb temperature areas such as those near 0℃. In addition, CWCTs often fail to achieve the designed cooling effect at low air wet-bulb temperatures. A experiment set of CWCT was built, and the performance of the CWCT at low air wet-bulb temperature near 0℃ was investigated. The impact of the operating parameters(air flow rate, cooling water flow rate, and spray water flow rate) on the heat and mass transfer performance of the CWCT was measured and analyzed. The results show the cooling performance of the CWCT at an air wet-bulb temperature 0℃, 2℃, and 4℃ is about 47%–63% of the rated operating condition;the optimal operating parameters of these conditions for the CWCT are just the same as those of the rated operating condition in summer. According to the experimental results, some operating advices are given. Closed wet cooling towers(CWCTs) are used widely because of their better water quality and smaller water consumption. However, the operating parameters shown in the technical documents are only for rated conditions in summer, not for any other conditions, especially in low air wet-bulb temperature areas such as those near 0°C. In addition, CWCTs often fail to achieve the designed cooling effect at low air wet-bulb temperatures. A experiment set of CWCT was built, and the performance of the CWCT at low air wet-bulb temperature near 0°C was investigated. The impact of the operating parameters(air flow rate, cooling water flow rate, and spray water flow rate) on the heat and mass transfer performance of the CWCT was measured and analyzed. The results show the cooling performance of the CWCT at an air wet-bulb temperature 0°C, 2°C, and 4°C is about 47%–63% of the rated operating condition; the optimal operating parameters of these conditions for the CWCT are just the same as those of the rated operating condition in summer. According to the experimental results, some operating advices are given.
出处 《Journal of Thermal Science》 SCIE EI CAS CSCD 2019年第5期1015-1023,共9页 热科学学报(英文版)
关键词 CLOSED wet COOLING TOWER performance of COOLING TOWER low AIR WET-BULB TEMPERATURE rated operating parameters evaluation index closed wet cooling tower performance of cooling tower low air wet-bulb temperature rated operating parameters evaluation index
  • 相关文献

参考文献2

二级参考文献5

共引文献9

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部