期刊文献+

CIC法定量测定TNT

Quantitative Determination of TNT by CIC Method of GC-AED
下载PDF
导出
摘要 采用气相色谱-原子发射光谱对TNT进行定量测定,建立了一种非含能非自身标样定量测定方法。以二号中定剂为外标物,通过二号中定剂的C元素标准曲线定量TNT中的C元素。结果表明:用二号中定剂作外标物定量TNT的C元素线性范围是22. 43~637. 50μg/mL,相关系数(r)为0. 999 9。以3倍信噪比计算检测限,得到TNT的C元素方法检测限为0. 015μg/mL。TNT在高、中、低浓度下的回收率为94. 6%~101. 3%,相对标准偏差为0. 3%~0. 7%。该方法具有较好的准确度和精密度,在自身标准物质缺乏的情况下能够对TNT进行准确定量。 The gas chromatography-atomic emission spectroscopy (GC-AED) was used to quantitatively measure TNT, and established a quantitative determination method of TNT by non-energetic non-self-standard samples. In this method, the dimethyl-diphenylurea was used as an external standard sample, and the C element in the TNT was quantified by the C element standard curve of the dimethyldiphenylurea. The results showed that the linear range of C element of TNT was 22.43~637.50 μg/mL, and the correlation coefficient (r) was 0.999 9. The detection limit was calculated by 3 times of the signal-to-noise ratio, and the detection limit of the C element method of TNT was 0.015 μg/mL. The recovery of TNT at high, medium and low concentrations was 94.6% to 101.3%, and the relative standard deviation was 0.3% to 0.7%. The method has good accuracy and precision. It can accurately quantify TNT in the absence of its own standard materials.
作者 罗西 刘红妮 苏鹏飞 张皋 胡银 王歌扬 温晓燕 LUO Xi;LIU Hongni;SU Pengfei;ZHANG Gao;HU Yin;WANG Geyang;WEN Xiaoyan(Xi’an Modern Chemistry Research Institute,Xi’an 710065,China)
出处 《兵器装备工程学报》 CAS 北大核心 2019年第2期208-210,共3页 Journal of Ordnance Equipment Engineering
基金 国防技术基础项目(JSZL2016208C006)
关键词 气相色谱-原子发射光谱 CIC法 定量分析 TNT 二号中定剂 gas chromatography-atomic emission spectroscopy CIC method quantitative analysis TNT dimethyldiphenylurea
  • 相关文献

参考文献8

二级参考文献95

共引文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部