针对火电厂锅炉补给水系统反渗透浓水及离子交换器再生废水量大,不能完全得到有效利用的问题,通过分析反渗透浓水及再生废水水质并探究回用其至循环水系统可能产生的影响,进行了合理性探究。得出的结论表明将反渗透浓水及再生废水回用至循环水系统是十分合理的,且节水效益明显提高。
The large amount of reverse osmosis concentrated water and ion exchanger reclaimed wastewater in boiler feed water systems of thermal power plants can not be fully utilized.By analyzing the quality of reverse osmosis concentrated water and reclaimed wastewater, reasonable exploring on the feasibility of reusing it into circulating water system is made.Conclusion is drawn that it is feasible to reuse reverse osmosis concentrated water and reclaimed wastewater into the circulating water system, and the water-saving benefit is obvious.
作者
李亚敏
郭廷晖
LI Yamin;GUO Tinghui(Huadian Luohe Power Generation Company Limited,Luohe 462300, China;HuadianZhengzhou Mechanical Design Institute Company Limited,Zhengzhou 450046, China)
出处
《华电技术》
CAS
2019年第2期60-64,共5页
HUADIAN TECHNOLOGY
关键词
反渗透浓水
再生废水
回收利用
循环水系统
reverse osmosis concentrated water
reclaimed wastewater
reusing
circulating water system