期刊文献+

射波刀脊柱追踪定位误差异常原因探讨 被引量:2

Detection of abnormal locating errors cause in Cyberknife X-sight spine tracking
下载PDF
导出
摘要 目的:研究和验证脊柱影像分割在射波刀脊柱追踪定位中的作用,探讨引起脊柱追踪定位异常的原因。方法:利用体模放疗计划改变脊柱追踪长度,通过错误节点的变化判断脊柱影像分割在脊柱追踪算法中的作用;对16例脊柱追踪异常病例分别添加或去除脊柱分割影像,观察脊柱追踪定位是否正常。结果:脊柱影像分割感兴趣区域中脊柱长度与错误节点呈负相关;16例脊柱追踪异常病例中,除1例因治疗中心距椎间隙过近需进行微移外,全部患者脊柱追踪定位正常。结论:脊柱影像分割不仅仅是为了方便影像比对,其还参与脊柱追踪定位误差的计算;脊柱影像是否分割是影响脊柱追踪定位的重要因素,应依据脊柱追踪区域影像密度的均匀性有选择地进行。 Objective To investigate and validate the role of spinal image segmentation in Cyberknife X-sight spine tracking. Methods The length of spine tracking was changed by the phantom radiography plan, and the role of spinal image segmentation images in spine tracking algorithm was defined by the changes of the false mesh nodes;combined with 16 cases of abnormal locating errors, spinal image segmentation images were added or deleted to observe whether the spine tracking location was normal. Results There was a negative correlation between the length of spinal image segmentation column and the false nodes in the ROI of spine tracking. In the 16 cases of abnormal spine tracking, all of the patients had been normally tracked except 1 case with the treatment center moved. Conclusion Spinal image segmentation is not only for convenience of image alignment to the technician, but also for calculating the locating errors to the target locating system. Spinal image segmentation is an important factor affecting the locating in Cyberknife X-sight spine tracking. Whether the spinal image is segmented depends on the image density homogeneity of the spine tracking region.
作者 赵瑞 张奋进 王震岳 陆军 李莎 ZHAO Rui;ZHANG Fen-jin;WANG Zhen-yue;LU Jun;LI Sha(Department of Radiation Oncology, the 940th Hospital of Joint Logistics Support Force, Lanzhou 730050, China)
机构地区 联勤保障部队第
出处 《医疗卫生装备》 CAS 2019年第2期68-70,78,共4页 Chinese Medical Equipment Journal
关键词 射波刀 脊柱追踪 脊柱影像分割 放射治疗 定位误差 数字重建放射影像 Cyberknife spine tracking spinal image segmentation radiotherapy locating error digital reconstructed radio-graphy
  • 相关文献

参考文献4

二级参考文献43

  • 1韩俊庆,盛巍,刘奇.CyberKnife在肿瘤立体定向放射治疗中的应用[J].国外医学(肿瘤学分册),2004,31(12):901-904. 被引量:11
  • 2于金明,任瑞美,袁明智,尹勇,岳金波.早期非小细胞肺癌三维适形放疗剂量分割研究[J].中华放射肿瘤学杂志,2005,14(3):158-161. 被引量:29
  • 3夏廷毅.立体定向高分次剂量放疗早期非小细胞肺癌[J].中华放射肿瘤学杂志,2006,15(4):342-344. 被引量:18
  • 4RomaneUi P, He.it G, Chang SD, et al. Cyberknife radiosurgery for trigeminal neuralgia [J]. Stereotact Funct Neurosurg, 2003, 81 (1-4):105 - 109. 被引量:1
  • 5RomaneUi P, Chang SD, Koong A, et al. Extracranial radiosurgery using the GyberKnife [j]. Techni Neurosurg, 2003, 9(3): 226-231. 被引量:1
  • 6oste-Maniere E, Olender D, Kilby W, et al. Robotic whole body stereotactic radiosurgery: clinical advantages of the Cyberknife integrated system [j]. IntJ Med Robot Comput Assist Surg, 2005, 1 (2): 28-39. 被引量:1
  • 7Kuo JS, Yu C, Petrovich Z, et al. The CyberKnife stereotactic radiosurgery system :description, installation,and an initial evaluation of use and functionality[j]. Neurosurgery, 2003, 53(5): 1235- 1239. 被引量:1
  • 8Yu C, Jozsef G, Apuzzo ML, et al. Dosimetric comparison of CyberKnife with other radiosurgical modalities for an ellipsoidal target[J]. Neurosurgery, 2003, 53(5): 1155- 1162. 被引量:1
  • 9Yu C, Jozsef G, Apuzzo ML, et al. Measurements of the relative output factors for CyberKnife collimators [J]. Neurosurgery, 2004, 54(1): 157-161. 被引量:1
  • 10Chang SD, Adler JR. Robotics and radlosurgery--the cyberknlfe [J]. Stereotact Funct Neurosurg, 2001, 76(3 -4): 204-208. 被引量:1