期刊文献+

气相色谱-质谱法测定卷烟主流烟气中的多环芳烃 被引量:2

Determination of Polycyclic Aromatic Hydrocarbons in Mainstream Cigarette Smoke by Gas Chromatography-Mass Spectrometry
下载PDF
导出
摘要 通过优化前处理条件,建立了卷烟主流烟气中16种多环芳烃的检测方法,并用该方法检测了8个牌号的卷烟样品。以环己烷超声萃取剑桥滤片中捕集的多环芳烃,固相萃取提纯,旋蒸浓缩,气相色谱质谱联用仪进行检测,方法的最佳超声萃取时间为20 min,固相萃取溶液流速不应超过2 mL/min,各化合物的检出限在0. 05 ng/cig至0. 18 ng/cig,以相对标准偏差表示的重复性不大于7. 66%,加标回收率在87. 15%至110. 73%,适用于卷烟主流烟气中多环芳烃的分析。 A method for detection of 16 polycyclic aromatic hydrocarbons(PAHs)in mainstream cigarette smoke was established by optimizing the pretreatment conditions,and 8 brands of marketed cigarette samples were determined by the developed method.PAHs were trapped by Cambridge filters and ultrasonic extracted by cyclohexane,purified by solid phase extraction(SPE)column,concentrated by evaporator,then detected by gas chromatography-mass spectrometer(GC-MS).The optimum ultrasonic extraction time was 20 min,and the flow rate of SPE solution should not exceed 2 mL/min.The detection limits of PAHs was in the range of 0.05 ng/cig to 0.18 ng/cig,the repeatabilities expressed as RSD were less than 7.66%,and the recovery rates were between 87.15% and 110.73%.The method was suitable for detecting PAHs in mainstream cigarette smoke.
作者 于航 尚梦琦 方一 李宁 YU Hang;SHANG Meng-qi;FANG Yi;LI Ning(Beijing Tobacco Quality Supervision and Inspection Station,Beijing 100029,China)
出处 《广州化工》 CAS 2019年第1期80-84,共5页 GuangZhou Chemical Industry
关键词 卷烟 主流烟气 气相色谱-质谱法 多环芳烃 固相萃取 cigarette mainstream smoke gas chromatography mass spectrometry polycyclic aromatic hydrocarbons solid phase extraction
  • 相关文献

参考文献9

二级参考文献120

共引文献51

同被引文献19

引证文献2

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部