摘要
本文对某水电厂一起功率波动事件进行分析,得出事件原因是调速器功率限制定值整定不当,并提出了整改措施。
In this paper,a power fluctuation event ofa hydropower plant was analyzed.The cause of the incident is improper tuning of the power limit value of the governor.Therefore the rectification measures were proposed.
作者
何伟焕
HE Waihuan(Sichuan Huaneng Kangding Hydropower Co.L td.,Chengdu 610041,China)
出处
《电工技术》
2018年第2期12-13,16,共3页
Electric Engineering
关键词
调速器
功率
波动
限值
governor
power
fluctuation
limit