期刊文献+

Chromatoprobe as a sample-sparing technique for residual solvent analysis of drug discovery candidates by gas chromatography 被引量:3

Chromatoprobe as a sample-sparing technique for residual solvent analysis of drug discovery candidates by gas chromatography
下载PDF
导出
摘要 In drug discovery research, residual solvent measurement is an integral part of purity analysis for synthesis of a drug candidate before it is used for toxicity testing. This is usually carried out using gas chromatography(GC)with direct injection sample introduction. This method requires testing compounds to be soluble at high concentrations( > 50 mg/mL, usually in DMSO) to achieve acceptable sensitivity, a hurdle which is not always achievable for some samples such as cyclic peptides and oligonucleotides. To overcome the limitation associated with the direct injection approach, a new method using the Chromatoprobe thermal extraction device was developed for quantifying residual solvents of drug discovery compounds. This method not only consumes significantly less material(less than 1 mg), but also shows higher sensitivity than the direct injection approach.In addition, because no diluent is required with the Chromatoprobe thermal extraction, all residual solvents can be detected and measured without further method optimization. In our study, we compared data from GC residual solvent analysis using the Chromatoprobe solid sample introduction to those of the direct injection method for seven in-house samples. Our results showed a good agreement between the data from these two sample introduction methods. Thus, the Chromatoprobe sample introduction method provided a samplesparing alternative to the direct injection method for the measurement of residual solvents in drug discovery.This method can be particularly useful for residual solvent analysis in samples that are available only in limited amounts, poorly soluble, and/or unstable in the diluents used for the direct injection method. In drug discovery research, residual solvent measurement is an integral part of purity analysis for synthesis of a drug candidate before it is used for toxicity testing. This is usually carried out using gas chromatography(GC)with direct injection sample introduction. This method requires testing compounds to be soluble at high concentrations( > 50 mg/mL, usually in DMSO) to achieve acceptable sensitivity, a hurdle which is not always achievable for some samples such as cyclic peptides and oligonucleotides. To overcome the limitation associated with the direct injection approach, a new method using the Chromatoprobe thermal extraction device was developed for quantifying residual solvents of drug discovery compounds. This method not only consumes significantly less material(less than 1 mg), but also shows higher sensitivity than the direct injection approach.In addition, because no diluent is required with the Chromatoprobe thermal extraction, all residual solvents can be detected and measured without further method optimization. In our study, we compared data from GC residual solvent analysis using the Chromatoprobe solid sample introduction to those of the direct injection method for seven in-house samples. Our results showed a good agreement between the data from these two sample introduction methods. Thus, the Chromatoprobe sample introduction method provided a samplesparing alternative to the direct injection method for the measurement of residual solvents in drug discovery.This method can be particularly useful for residual solvent analysis in samples that are available only in limited amounts, poorly soluble, and/or unstable in the diluents used for the direct injection method.
机构地区 Bristol-Myers Squibb
出处 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2017年第4期265-269,共5页 药物分析学报(英文版)
关键词 Chromatoprobe Thermal extraction Gas CHROMATOGRAPHY RESIDUAL SOLVENT DRUG discovery Chromatoprobe Thermal extraction Gas chromatography Residual solvent Drug discovery
  • 相关文献

同被引文献24

引证文献3

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部