摘要
在全厂失电条件下,应急电力系统的蓄电池组是唯一能够提供反应堆电力的可靠电源。为测定蓄电池组的使用寿命,我们采用加速老化试验方法对其进行了试验,通过数据分析找到了表征电池失效的电气特征参数。
The batteries in the emergency power system are the only reliable power supply to the reactor under the condition of loss of electricity in the plant.By using the accelerated aging test method and analyzing data,we find the electric characteristic parameters of the battery failure in order to determine their service lives.
作者
夏明
靳宏伟
谢俊
王学杰
XIA Ming;JIN Hongwei;Xie Jun;WANG Xuejie(Institute of Nuclear Physics & Chemistry, China Academy of Engineering Physics, Mianyang Sichuan 621900;PLA 91515, Sanya Hainan 572016, China)
出处
《蓄电池》
2017年第3期137-141,共5页
Chinese LABAT Man