本文通过Li/SOCl2电池在室温、高温下的放电试验,对该电池的有效期等可靠性管理问题进行了讨论。电量测量的结果表明,初始电量不足是造成电池早期失效的原因之一。
The problems to the term of validty and other thigs in reliability managenent of Li/SOCl2 were discussed by the test of capacty measurement. The results of the test reveal that low-capaeity is one of the main causes to the cells' early failure in its period of storage time.
出处
《长春理工大学学报(自然科学版)》
1995年第1期19-22,共4页