摘要
通过大量实验得到了不同湿度、等效盐密条件下单个绝缘子起晕电压、起晕概率。实验表明 ,单个绝缘子起晕概率符合统计分布。利用曲线拟合方法建立了起晕电压与相对湿度、等效盐密的关系式 。
Based on a large number of tests, the corona inception voltage and corona possibility under different humidity and ESDD is obtained. The results show that the corona inception voltage contents to a statistical rule. Through curve fitting, the relationship equation between corona inception voltage and humidity and ESDD is found. It will be instructive to diagnosis on-line on defective insulators.
出处
《高电压技术》
EI
CAS
CSCD
北大核心
2002年第8期19-21,共3页
High Voltage Engineering