壳管式换热器在污水源热泵系统中间接提取污水热源,用这种换热器作为城市污水与清水之间的换热器,间接降低污水对机组的腐蚀损害.本文采用壳管式换热器作为污水与水间的换热器,首先对其进行结构设计计算,然后根据设计参数分析污水流速对堵塞换热的影响规律.
The shell-tube sewage heat exchanger usually was chosen as the heat transfer equipment in the sewage source heat pump system to decrease the damage to the whole system components. The paper designed it and analyzed the sewage velocity effect on the blocking heat transfer and concluded the effect rule.
作者
秦娜
付文成
QIN Na;FU Weng-cheng(Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control,National Demonstration Center for Experimental Mechanical and Electrical Engineering Education(Tianjin Unirersity of Technology),School of Mechanical Engineering,Tianjin University of Technology,Tianjin 300384,China)
出处
《天津理工大学学报》
2018年第5期6-8,共3页
Journal of Tianjin University of Technology
基金
天津市应用基础研究计划(15JCQNJC06800)
关键词
壳管式
污水换热器
堵塞
换热系数
shell-tube
sewage heat exchanger
blocking
heat transfer coefficient