七氟烷呼气末浓度与新鲜气流量、蒸发罐刻度关系的观察

Observation on the Relationship Between End-expiratory Concentration of Sevoflurane and Fresh Gas Flow and Scale of Evaporation Tank
下载PDF
导出
摘要 目的找到效率较高的新鲜气流量与蒸发罐刻度组合。方法将择期行气管插管全身麻醉患者90例随机分为A、B、C 3组。全麻诱导气管插管完成后5 min(T0),记录MAP、HR和BIS值,然后设置A组新鲜气流量2 L/min,七氟烷蒸发罐刻度为3%,B组为3 L/min和2%、C组为4 L/min和1.5%,每组30例,记录3组七氟烷呼气末浓度达到1.2%(即0.7 MAC)所需的时间(s),以及到达目标浓度后3分钟内(T1)MAP、HR和BIS的最低值。结果 3组患者七氟烷呼气末浓度达到1.2%(即0.7 MAC)所需的时间,A组小于B组,B组小于C组(P<0.05);比较3组患者T1时的MAP、HR、BIS比T0时下降的百分比,无统计学差异。结论较低新鲜气流量联合较高七氟烷蒸发罐刻度,其效率优于较高新鲜气流量联合较低七氟烷蒸发罐刻度。 Objective To find a more efficient combination of fresh gas flow and scale of evaporation tank. Methods 90 patients underwent elective intubation with general anesthesia were randomly divided into Group A,Group B,and Group C. 5 minutes after induction of tracheal intubation( T0),MAP,HR and BIS were recorded. Then the following values were set up: fresh gas flow of Group A was 2 L/min,scale of evaporation tank was 3%,Group B was 3 L/min and 2%,Group C was 4 L/min and 1. 5%,with30 cases in each group. The time required for the end-expiratory concentration of sevoflurane in 3 groups to reach 1. 2 %( 0. 7 MAC)was recorded and the lowest values of MAP,HR and BIS within 3 minutes after reaching the target concentration( T1) was recorded.Results The time required for the end-expiratory concentration of sevoflurane in 3 groups to reach 1. 2%( 0. 7 MAC) was as follows:Group A was shorter than Group B,Group B was shorter than Group C( P〈0. 05),the decreasing percentages of MAP,HR,and BIS from T0 to T1 in 3 groups weren't statistically different. Conclusion The efficiency of lower fresh gas flow combined with higher sevoflurane evaporation tank scale was better than that of higher fresh gas flow combined with lower sevoflurane evaporation tank scale.
作者 张霞 朱跃坤 陈永喜 顾利华 Zhang Xia;Zhu Yuekun;Chen Yongxi;Gu Lihua(Department of Anesthesiology,Wuzhong People蒺s Hospital of Suzhou,Suzhou 215128 China)
出处 《锦州医科大学学报》 CAS 2018年第4期62-64,共3页 Journal of Jinzhou Medical University
关键词 七氟烷 呼气末浓度 新鲜气流量 蒸发罐刻度 sevoflurane end-expiratory concentration fresh gas flow scale of evaporation tank
  • 相关文献

参考文献5

二级参考文献33

  • 1杨芃,黄文起.七氟醚在成人门诊手术中的应用[J].临床麻醉学杂志,2006,22(3):239-240. 被引量:84
  • 2孙艳红,崔湧,王俊科.七氟醚对内毒素诱导大鼠肺组织氧化应激反应的影响[J].中华麻醉学杂志,2006,26(8):735-737. 被引量:34
  • 3李勇,王杨,汪小海.七氟醚和氟烷在小儿唇腭裂手术麻醉中应用的比较[J].临床麻醉学杂志,2006,22(12):943-943. 被引量:10
  • 4庄心良 曾因明 陈伯銮.现代麻醉学[M](第3版)[M].北京:人民卫生出版社,2004.1301-1325. 被引量:32
  • 5Bauerle K, Greim CA, Schroth M, et al. Prediction of depth of sedation and anaesthesia by the Narcotrend EEG monitor. Br J Anaesth, 2004, 92:841-845. 被引量:1
  • 6Cheong KF, Teh TS. Sevoflurane induction in the elderly. Med J Malaysia, 2001, 56:446-450. 被引量:1
  • 7Siddik-Sayyid SM, Aouad MT, Taha SK, et al. A comparison of sevoflurane-propofol versus sevoflurane or propofol for laryngeal mask airway insertion in adults. Anesth Analg, 2005, 100:1204-1209. 被引量:1
  • 8MakenaPS,GorantlaVK,GhoshMC,etal.Lunginjurycausedbyhightidalvolumemechanicalventilationandhyperoxiaisdepend-entonoxidant-mediatedc-JunNH2-terminalkinaseactivation[J].JApplPhysiol,2011,111(5):1467-1476. 被引量:1
  • 9PruszkowskiO,DalibonN,MoutafisM,etal.Effectsofpropofolvs.sevofluraneonarterialoxygenationduringonelungventilation[J].BrJAnaesth,2007,98(4):539-544. 被引量:1
  • 10VoigtsbergerS,LachmannRA,LeutertAC,etal.Sevofluraneamel-ioratesgasexchangeandattenuateslungdamageinexperimentallipopolysaccbaride-inducedlunginjury[J].Anesthesiology,2009,111(6):1238-1248. 被引量:1

共引文献44

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部