期刊文献+

某工业区污水处理厂污水处理工艺设计 被引量:10

Design of Process for Wastewater Treatment Plant in an Industrial Park
下载PDF
导出
摘要 上海某工业区拟建污水处理厂近期设计规模为7.5万m3/d,其中工业废水量比例达到73%。在水质分析的基础上,采用"水解酸化+改良AAO+深度处理"的主体工艺方案,建立多水质工况的运行模式,并通过试验研究和模型分析优化设计参数,确保出水达到一级A标准。 Design wastewater treatment capacity in a proposed wastewater treatment plant located in an industrial park of Shanghai is 75 000 m^3/d in the near future. 73% proportion of the treated volume is industrial wastewater. On the basis of water quality analysis, combined process of hydrolytic acidification, modified AAO and advanced treatment is adopted. And multiple operation modes are established for different water quality conditions. Design parameters are optimized through experiment and model analysis. After applying the measures above,it can ensure the effluent quality meet the first level A criteria.
作者 高原 Gao Yuan(Shanghai Urban Construction Design & Research Institute 〈 Group 〉 Co.,Ltd.,Shanghai 200125,China)
出处 《净水技术》 CAS 2018年第7期91-96,共6页 Water Purification Technology
基金 国家水体污染控制与治理科技重大专项(2013ZX07304-003)
关键词 工业区 污水厂 水解酸化 改良AAO 深度处理 一级A标准 industrial park wastewater treatment plant (WWTP) hydrolytic acidification modified AAO advanced treatment first level A criteria
  • 相关文献

参考文献2

二级参考文献14

  • 1李鑫玮,牛庆利,周军,甘一萍,吕鑑.BioWin在污水脱氮除磷系统中的应用研究[J].水工业市场,2009(11):38-41. 被引量:10
  • 2沈童刚,邱勇,应启锋,葛勇涛,施汉昌,曾思育,何苗,胡志荣.污水处理厂模拟软件BioWIN的应用[J].给水排水,2009,35(S1):459-462. 被引量:30
  • 3北京水环境技术与设备研究中心,北京市环境保护科学研究院,国家城市环境污染控制工程技术研究中心.三废处理工程技术手册[M].北京:化学工业出版社,2000. 被引量:1
  • 4Henze M.,Grady C. P. L. Jr.,Gujer W. , et al. ActivatedSludge Model No. 1,Scientific and Technical Report No. 1.London,England ; IAWPRC,1987. 被引量:1
  • 5Gujer W. ,Henze M. , Mino T. , et al. The activated sludgemodel No. 2 : Biological phosphorus removal. Water Scienceand Technology, 1995 ,31 (2) :1-11. 被引量:1
  • 6Henze M.,Gujer W. ,Mino T. ,et al. Activated sludge mod-el No. 2D, ASM2D. Water Science and Technology, 1999,39(1) :165-182. 被引量:1
  • 7Gujer W.,Henze M. ,Mino T. ,et al. Activated sludge mod-el No. 3. Water Science and Technology, 1999,39 ( 1 ):183-193. 被引量:1
  • 8沈童刚,邱勇,施汉昌.用BioWIN软件模拟优化城市污水处理厂运行的研究//2008年全国污水处理节能减排新技术新工艺新设施高级研讨会论文集,2008 :106-112. 被引量:1
  • 9髙红伟.BioWin软件对污水处理厂运行的模拟优化研究.北京:北京建筑大学硕士学位论文,2013:34-41. 被引量:1
  • 10Oliveira C. S. ,Ordaz A. ,Ferreira E. C. ,et al. In situ pulserespirometric methods for the estimation of kinetic and stoi-chiometric parameters in aerobic microbial communities. Bi-ochemical Engineering Journal ,2011,58-59 : 12-19. 被引量:1

共引文献13

同被引文献21

引证文献10

二级引证文献30