期刊文献+

预制混凝土柱采用套筒灌浆连接与螺栓连接的抗震性能对比研究 被引量:6

Comparative study on seismic behavior of precast concrete column with grout sleeve splicing and bolt connection
下载PDF
导出
摘要 通过对3个套筒灌浆连接和3个螺栓连接的预制混凝土柱在低周反复荷载作用下的试验研究,对比分析了两种连接方式在不同轴压比作用下的破坏形态、破坏模式、试验曲线、连接构造对抗震性能的影响。结果表明:轴压力的作用能够有效增强试件的耗能能力,套筒灌浆连接试件与螺栓连接试件的承载力相当,加载后期其刚度退化速率更小,位移延性更好。 The experimental study of three grout sleeve splicing specimens and three bolt connection specimens under low cyclic reversed loading has been chose to analysis the failure patterns,failure modes,curves,connections influence to seismic behavior of these two connections under different axial compression ratio. It's shows that the axial pressure can effectively enhance the energy dissipation capacity of specimens,the bearing capacity of these two connections are relatively close,but the stiffness degradation rate in the later loading stage of grout sleeve splicing specimens is smaller and its displacement ductility is better than bolt connection specimens.
作者 黄朗 赵勇 刘汉昆 刘攀 HUANG Lang;ZHAO Yong;LIU Hankun;LIU Pan(Siehuan Institute of Building Research,Chengdu 610081,China;School of Civil Engineering,Tongji University,Shanghai 200092,China)
出处 《四川建筑科学研究》 2018年第3期23-27,38,共6页 Sichuan Building Science
基金 国家重点研发计划(2017YFC0702900)
关键词 套筒灌浆连接 螺栓连接 破坏模式 抗震性能 grout sleeve splicing bolt connection failure modes seismic behavior
  • 相关文献

参考文献6

二级参考文献18

  • 1DBJ/CT082-2010润泰预制装配整体式混凝土房屋结构体系技术规程[s].上海:上海市建筑建材业市场管理总站,2010. 被引量:1
  • 2Splice-sleeve north America [ EB/OL i. http://www. splicesleeve, corn/. ACI 550. 被引量:1
  • 31R-OI Emulating east-in-place detailing in precast concrete structures [ S ]. American Concrete Institute, Farmington Hills, Michigan, 2001. 被引量:1
  • 4Erico lenton Q interlok [ EB/OL ]: http://www, erico, corn/ products/INTERLOK, asp. 被引量:1
  • 5Einea, Yamane T, Tadros. Grout-filled pipe splices tot precast concrete construction [ J]. PCI Journal, 1995,40( l ) :82-93. 被引量:1
  • 6Ong tlern Yee. Experimental study of grout filled splice sleeve integrated with shear key for precast concrete connection [ D]. University Technology MALAYSIA, 2010. 被引量:1
  • 7ASTM A1034-10a Standard test method tar testing mechanical splices for steel reinforcing bars [ S ]. ASTM. West Conshohocken, PA ,2010. 被引量:1
  • 8ACI 318-08 Building code requirements for structural concrete and commentary [ S]. American Concrete Institute, Farmington Hills, Michigan, 2005. 被引量:1
  • 9中国建筑科学研究院.JG1107-2010钢筋机械连接技术规程[S].北京:中国建筑工业出版社,2010. 被引量:1
  • 10Belleri, Riva P. Seismic behavior of precast column-to- foundation grouted sleeve connections [ C]//The 14th World Conference on Earthquake Engineering. 2008. 被引量:1