期刊文献+

Effect of hemoperfusion cartridge on different internal environmental indicators 被引量:1

Effect of hemoperfusion cartridge on different internal environmental indicators
下载PDF
导出
摘要 BACKGROUND:This study aimed to observe the effect of hemoperfusion(HP) cartridge on different internal environment indicators at different time points in patients with acute blood poisoning and to find alternative indicators for the detection of blood poisoning.METHODS:The levels of internal environment indicators(blood pH,P_vCO_2,P_vCO_2,blood lactate,potassium,free calcium,bicarbonate,and blood glucose) before and after HP treatment were recorded for patients with acute poisoning at time points of 30 minutes and 120 minutes.After calculating the difference value 5,the statistical software was used to analyze the statistical difference of the influence caused by HP cartridge at two time points.According to the formula,adsorption rate%=(a-v)/a×100,the adsorption rate of each indicator was calculated respectively.RESULTS:The difference of indicators at different time points in inlet and outlet such as blood glucose,free-calcium,and lactate was statistically significant(P<0.05),but the difference in indicators such as pH,P_vCO_2,P_vO_2,potassium,sodium,and bicarbonate was not statistically significant(P>0.05).CONCLUSION:During HP treatment,the indicators of blood glucose,free-calcium and lactate were significantly affected by HP cartridge,and the effect varies with time. BACKGROUND: This study aimed to observe the effect of hemoperfusion (HP) cartridge on different internal environment indicators at different time points in patients with acute blood poisoning and to find alternative indicators for the detection of blood poisoning. METHODS: The levels of internal environment indicators (blood pH, PvCO2, PRO2, blood lactate, potassium, free calcium, bicarbonate, and blood glucose) before and after HP treatment were recorded for patients with acute poisoning at time points of 30 minutes and 120 minutes. After calculating the difference value 6, the statistical software was used to analyze the statistical difference of the influence caused by HP cartridge at two time points. According to the formula, adsorption rate %= a-v/a×100, the adsorption rate of each indicator was calculated respectively. RESULTS: The difference of indicators at different time points in inlet and outlet such as blood glucose, free-calcium, and lactate was statistically significant (P〈0.05), but the difference in indicators such as pH, PvCO2, PvO2, potassium, sodium, and bicarbonate was not statistically significant (P〉0.05). CONCLUSION: During HP treatment, the indicators of blood glucose, free-calcium and lactate were significantly affected by HP cartridge, and the effect varies with time.
出处 《World Journal of Emergency Medicine》 CAS 2013年第4期290-293,共4页 世界急诊医学杂志(英文)
关键词 Hemoperfusion cartridge Internal environment indicators Blood glucose Adsorption rate Hemoperfusion cartridge Internal environment indicators Blood glucose Adsorption rate
  • 相关文献

参考文献3

二级参考文献11

共引文献21

同被引文献27

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部