介绍了新疆中泰化学(集团)阜康能源有限公司膜法除硝技术改造情况及改造后冷冻系统的运行情况,总结了在冷冻系统建立温度体系过程中出现的问题,并提出了相应的改进措施。
The improvements that Xinjiang Zhongtai chemical (Group) Fukang Energy Co. , Ltd. carried out on membrane-process sulfate removal technology are introduced. The operation of refrigeration system after the improvements is also introduced. The problems in the establishment of temperature system of the freezing system are summarized, and the corresponding countermeasures are put forward.