摘要 目的探讨经皮椎间盘镜(MED)及椎间孔镜技术(TESSYS)下行L_5/S_1腰椎间盘突出髓核摘除术后对腰椎生物力学稳定性的影响。方法选取自2014年1月~2016年12月确诊为腰椎间盘突出症(单阶段,L_5/S_1)在我院接受治疗的病人。根据治疗方式分为对照组:保守治疗患者50例,MED组52例,TESSYS组43例。比较MED组、TESSYS组及对照组L_5/S_1节段经治疗6个月、12个月、24个月后,前屈、后伸、左右侧屈的运动范围改变情况。结果 MED组和TESSYS组术后L_5/S_1节段前屈、后伸及左右侧屈运动范围较对照组相比,差异无统计学意义(P>0.05),并且未发现腰椎不稳。结论腰椎间盘突出症患者行MED和TESSYS手术治疗后,尽管腰椎正常结构遭到破坏,活动范围增加,但短期内不会破坏腰椎稳定性。 Objective To study the effect on L5/S1 lumbar spine stability after the treatment of microendoscopic lumbar discectomy( MED) and transforaminal endoscopic spine system( TESSYS). Methods Patients who were diagnosed with lumbar disc herniation( single stage,L5/S1) treated in our hospital from January 2014 to December 2016 were selected. According to the treatment methods,the patients were divided into three groups. The control group: 50 patients with conservative treatment; MED group: 52 patients; TESSYS group: 43 patients. Range of lumbar flexion,extension and lateral flexion after treatment of 6 months,12 months,24 months were compared. Results Compared with range of flexion,extension and lateral flexion in L5/S1 segmental of MED group and TESSYS group after surgery,the difference was not statistically significant( P〉0. 05),and there was no finding lumbar instability. Conclusion After the operation of MED and TESSYS in the patients with lumbar disc herniation,the range of motion increases,but the stability of the lumbar spine will not be disturbed in the short term,although the normal structure of the lumbar spine is damaged. The long term outcome needs further study.
出处 《潍坊医学院学报》 2017年第6期405-407,451,共4页 Acta Academiae Medicinae Weifang
关键词 经皮椎间盘镜技术 经皮椎间孔镜技术 腰椎间盘突出症 生物力学 Percutaneous discectomy technique Percutaneous transforaminal endoscopic Discectomy lumbar disc herniation Biomechanics
  • 相关文献

参考文献4

二级参考文献45

  • 1David Spenciner, David Greene, James Paiva, et al. The multidirectional bending properties of the human lumbar intervertebral disc [ J ]. Spine, 2006, 6 : 248. 被引量:1
  • 2Ng H W, Teo E C, Lee K K, et al. Finite element analysis of cervical spinal instability under physiologic loading [ J ] . J Spinal Disord Tech, 2003, 16 (1):55. 被引量:1
  • 3AMUNDSEN T, WEBER H, LILLEAS F. Lumbar spinal stenosis. Clinical and radiologic feature[J']. Spine (Phila Pa 1976), 1995, 20(10): 1178-1186. 被引量:1
  • 4SCHOFFERMAN J, REYNOLDS J, HERZOG R, et al. Failed back surgery: etiology and diagnostic evaluation[J]. Spine (Phila Pa 1976), 2003, 3(5): 400-403. 被引量:1
  • 5WILKE H, NEEF P, HINZ B, et al. Intradiscal pressure together with anthropometric data--a data set for the validation of models[J]. Clin Biomech , 2001, 16 (Suppl 1): S111- S126. 被引量:1
  • 6LU Y M, HUTTON W C,GHARPURAY V M. Do bending, twisting,and diurnal fluid changes in the disc affect the propensity to prolapse A viscoelastic finite element model [J].Spine (Phila Pa 1976) , 1996, 21(22): 2570-2579. 被引量:1
  • 7BOWDEN A E, GUERIN H L, VILLARRAGA M L, et al. Quality of motion eonsiderations in numerical analysis of mo- tion restoring implants of the spine[J]. Clinical Biomeehanics, 2008, 23(5): 536-544. 被引量:1
  • 8AHMAD F, KOICHI S, GOEL V K, et al. Biomeehanical rationale of ossification of the secondary ossification center on apophyseal bony ring fracture: a biomechanical study [J]. Clinical Biomechanics, 2007, 22(10): 1063-1067. 被引量:1
  • 9ANTONIUS R, NAGANANDA K, BURRA J. Comparison of the effects of bilateral posterior dynamic and rigid fixation devices on the loads in the lumbar spine:a finite element analysis[J].Eur Spine J, 2007(16) : 1223-1231. 被引量:1
  • 10POLIKEIT A, NOLTE L P, FERGUSON S J. The effect of cement augmentation on the load transfer in an osteoporotie functional spinal unit, finite-element analysis [J]. Spine, 2003, 28(10): 991-996. 被引量:1