摘要
金属冶炼厂电源的整流设备要求比较高,大功率整流设备分为两种常用接线方式,即三相桥式相同逆并联连接线与双反星形带平衡电抗器同相逆并联接线,分别对这两种接线方式的工作原理及使用性能进行详细的分析与比较。
Rectifying equipment for metal smelting factory power supply requirements are relatively high,high power rectifier equipment is divided into two kinds of commonly used connection mode,namely the same inverse parallel connected three-phase bridge line and double anti star balance reactor cophase counter parallel connection,respectively,the working principle of the two kinds of connection mode and the performance of the detailed analysis and comparison.
出处
《世界有色金属》
2017年第23期47-48,共2页
World Nonferrous Metals
关键词
冶炼厂
整流器
双反星型接线
三相桥式接线
同相逆并联
smelter
connection mode of dual inverse-star type
connection mode of three-phase bridge
connection mode of cophase counter parallel