期刊文献+

2种免疫检验方法检测乙型肝炎病毒感染血清学标志物的临床研究 被引量:17

Clinical Study on Two Kinds of Immunoassay Methods for Detecting Serological Markers of Hepatitis B Virus Infection
下载PDF
导出
摘要 目的分析并比较两种不同免疫方法检测乙型肝炎病毒感染血清学标志物的临床效果。方法方便选取在2016年3月—2017年5月期间在该院收治并确诊的乙型肝炎感染患者100例,对100例患者分别采取电化学发光法(ECLIA)和酶联免疫吸附法(ELISA)来检测感染血清标志物,并将两种免疫检验方法的临床效果进行分析对比。结果酶联免疫吸附法诊断准确率(75.0%)明显低于电化学发光法诊断准确率(98.0%),且差异有统计学意义(P<0.05)。结论电化学发光法和酶联免疫吸附法分别对乙肝病毒感染血清进行检测,将结果进行比较,电化学光法的临床效果明显强于酶联免疫吸附法。 Objective This paper tries to analyze and compare the clinical effects of two different immunological methods on the detection of blood serological markers of hepatitis b virus. Methods 100 patients diagnosed with hepatitis b infection from March 2016 to May 2017 in this hospital were convenient selected and were respectively adopt electrochemical luminescence(ECLIA) and enzyme-linked immunosorbent(ELISA) to detect serum marker of infection, and the clinical effect of these two immunity test methods were compared and analyzed. Results The diagnostic accuracy of ELISA was 75.0%, significantly lower than the diagnostic accuracy of ECLIA of 98.0%, and the difference was statistically significant(P0.05).Conclusion The serum hepatitis b virus(HBV) infection has been tested by electrochemical luminescence method and enzyme-linked immunosorbent method respectively, the clinical effect of the electrochemical method is better than the enzyme-linked immunosorbent method.
作者 付林平
出处 《中外医疗》 2017年第32期21-23,共3页 China & Foreign Medical Treatment
关键词 电化学发光法 酶联免疫吸附法 乙型肝炎 病毒感染 血清学标志物 Elect rochemical luminescence Enzyme- l inked immunosorbent method Hepat i t is b Virus infect ion Markers of serology
  • 相关文献

参考文献9

二级参考文献92

共引文献127

同被引文献81

引证文献17

二级引证文献65

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部