期刊文献+

胸腰椎骨折单侧固定的有限元探讨 被引量:1

Finite element analysis of unilateral fixation of thoracolumbar fractures
下载PDF
导出
摘要 目的:通过有限元运算方法探讨胸腰椎骨折单侧固定的生物力学效果和可行性。方法:采用正常健康志愿者数据构建胸腰椎骨折有限元模型,装配单侧固定系统和双侧固定系统,对其进行有限元运算模拟。结果:通过有限元运算获得的结果分析,采取单侧固定的静态应力、最大应力与最大位移都明显提示较双侧固定不稳定(P<0.05)。结论:胸腰椎骨折采取单侧固定后其有限元运算的结果提示其生物力学效应较差,在临床应用中单侧固定选择需要慎重,避免矫形复位手术的失败。 Objective: Thoracolumbar fractures posterior orthopedic fixation program there are many, but unilateral fixation in clinical practice is not selected by physicians. The finite element method can simulate the biomechanical effects of internal fixation surgery in the computer. The biomechanical effect and feasibility of unilateral fixation of thoracolumbar fractures were explored by this method. Methods: The finite element model of thoracic and lumbar vertebrae fractures was constructed by normal healthy volunteer data. The unilateral fixation system and bilateral fixation system were used to simulate the finite element model. Results: The static stress, maximum stress and maximal displacement of unilateral fixation were significantly higher than those of bilateral fixation(P〈0.05), which were obtained by finite element analysis. Conclusion: Unilateral fixation of thoracolumbar fractures after its finite element operation results suggest that the biomechanical effects of poor clinical application of unilateral fixed choice need to be careful to avoid the failure of orthopedic reduction surgery.
出处 《临床与病理杂志》 2017年第9期1921-1925,共5页 Journal of Clinical and Pathological Research
基金 南京军区医学科技创新课题(12MA080) 南京军区南京总医院军事医学培育课题(YYMS2014002)~~
关键词 胸腰椎骨折 单侧固定 生物力学 静态应力 应力云图 位移量图 thoracolumbar fracture unilateral fixation biomechanics static stress stress cloud displacement diagram
  • 相关文献

参考文献6

二级参考文献55

  • 1徐海栋,陈勇,许斌,赵建宁.单侧椎弓根螺钉内固定椎间融合治疗腰椎退行性病变临床研究[J].医学研究生学报,2011,24(12):1268-1271. 被引量:18
  • 2范顺武,方向前,赵兴,赵凤东,虞和君.微创经椎间孔腰椎椎体间融合术治疗下腰椎疾病[J].中华骨科杂志,2007,27(2):81-85. 被引量:54
  • 3Chen HH,Cheng HH,Wang WK,et al.Biomechanical analysis ofunilateral fixation with interbody cagesSPINE,2005. 被引量:1
  • 4Goel VK,Lim TH,Gwon J,et al.Effects of rigidity of an internal fixation device: a comprehensive biomechanical investigationSPINE,1991. 被引量:1
  • 5Kabins MB, Weintein JN, Spratt KF, et al. Isolated L4-Ls fusions using the variable screw placement system: unilateral versus bilateral. Spine (Phila Pa 1976), 1992, 5(1): 39-49. 被引量:1
  • 6Deutsch H, Musacchio MI Jr. Minimally invasive transforaminal lum- bar interbody fusion with unilateral pedicle screw fixation. Neurosurg Focus, 2006, 20(3): El0. 被引量:1
  • 7Beringer WF, Mobasser ]P. Unilateral pedicle screw instrumentation for minimally invasive transforaminal lumbar interbody fusion. Neu- rosurg Focus, 2006, 20(3): E4. 被引量:1
  • 8Tuttle J, Shakir A, Choudhri HF. Paramedian approach for transfo- raminal lumbar interbody fusion with unilateral pedide screw fixation technical note and preliminary report on 47 cases. Neurosurg Focus, 2006, 20(3): ES. 被引量:1
  • 9Cloward R. The treatment of ruptured lumbar intervertebral discs by vertebral body fusion. J Neurosurg, 1953, 10(2): 154-168. 被引量:1
  • 10Ozdemir HM, Us AK, On T. The role of anterior spinal instrumen- tation and allograff fibula for the treatment ofpott disease. Spine (Phila Pa 1976), 2003, 28(5): 474-479. 被引量:1

共引文献66

同被引文献2

引证文献1

二级引证文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部