期刊文献+

空气中痕量三甲胺的顶空气相色谱-质谱法测定 被引量:3

Determination of Trace Trimethylamine in Air by Headspace Gas Chromatography/Mass Spectrometry
下载PDF
导出
摘要 建立了顶空气相色谱-质谱法测定空气中三甲胺(TMA)含量的方法。以0.02mol/L盐酸为吸收液采集空气中的三甲胺,吸收液用氢氧化钠游离出三甲胺,在80℃下平衡40min后用气相色谱-质谱联用仪进行检测。当采气流量为0.5L/min时,三甲胺的采集效率>99%;方法在0.05~2μg范围内线性良好,相关系数>0.999;做了3个水平的加标回收率和精密度实验,相对标准偏差在2.4%~5.6%,加标回收率在94%~102%;当采样体积为30L时,方法的检出限为0.3μg/m。所建方法灵敏度高于目前的主要分析方法,适用于环境空气中低浓度三甲胺的监测。 A method was developed for determination of trimethylamine( TMA) in air by headspace gas chromatography/mass spectrometry. Trimethylamine in air was collected with 0. 02 mol/L hydrochloric acid as absorbing solution. Then the trimethylamine in absorbing solution was released out by sodium hydroxide and determined by gas chromatography/mass spectrometry after equilibration for 40 minutes at 80℃. The collection efficiency was above 99% in a collection flow rate of 0. 5 L/min. Under the optimal conditions,the calibration curves were linear in the range of 0. 05 ~ 2. 0μg with correlation coefficient higher than 0. 999. The recoveries ranged from 94% to102% at three spiked levels. The relative standard deviations( RSD) were between 2. 4% and 5. 6%. Method determination limit was 0. 3μg/m3 in a collection volume of 30 L. The established method is more sensitive than other current analysis method,and is suitable fordetermination of trace level of trimethylamine in ambient air.
作者 黄长春
出处 《环境科学导刊》 2017年第4期86-89,共4页 Environmental Science Survey
关键词 三甲胺 空气 检测 顶空 气相色谱-质谱 trimethylamine air determination headspace GC-MS