期刊文献+

iTrace像差仪在Toric人工晶状体植入术后轴位测量中的应用 被引量:5

Application of iTrace aberration in measuring lens alignment after Toric intraocular lens implantation
下载PDF
导出
摘要 目的研究和评价利用iTrace像差仪在不散瞳情况下测量Toric人工晶状体(Toric intraocular lens,Toric IOL)轴位。方法收集2015年6月至2016年2月在天津医科大学眼科医院接受超声乳化白内障吸出联合Toric IOL植入术的白内障患者35例(45眼),术后1周随访,并行iTrace像差仪的检查。用眼内像差散光轴位换算为术后Toric IOL轴位,结果与传统裂隙灯测得的Toric IOL轴位做比较,分析其差异及相关性。结果患者术后1周裸眼视力和术后最佳矫正视力分别为(0.19±0.12)Log MAR和(0.10±0.09)Log MAR,42眼(93.3%)的裸眼视力≥20/40。传统裂隙灯法和iTrace法测得的Toric IOL轴位旋转分别为3.13°±2.86°(0°~9°)和4.44°±3.42°(0°~13°),两者比较差异有统计学意义(t=-2.321,P=0.025);两种方法测得的Toric IOL轴位差值的绝对值为3.67°±3.59°(0°~14°),差值结果中32眼(71.1%)<5°,9眼(20.0%)为5°~10°,4眼(8.9%)>10°。两种方法测得的Toric IOL轴位呈线性相关(r=0.926,P<0.01)。结论运用i Trace像差仪可以在不散瞳的情况下准确测量Toric IOL轴位,其结果具有一定的参考价值。 Objective To research and evaluate measuring Toric intraocular lens(Toric IOL) alignment by iTrace aberration without mydriasis.Methods Forty-five eyes of 35 patients underwent phacoemulsification in Tianjin Medical University Eye Hospital from June 2015 to February 2016 were enrolled.Follow-up and iTrace aberration examination were performed at postoperative 1 week.The internal optics aberration astigmatism axis was transformed into postoperative Toric IOL alignment.The result and the Toric IOL alignment measured by tradition slitlamp method were compared by linear correlation and difference.Results At postoperative 1week,the uncorrected distant visual acuity and corrected distant visual acuity were(0.19±0.12)LogMAR and(0.10±0.09) LogM AR.The UCVA was 20/40 or better in 42 eyes(93.3%).The mean IOL misalignment measured by slitlamp was(3.13±2.86) degrees(ranged 0-9 degrees) and by the iTrace aberration was(4.44±3.42) degrees(ranged 0-13 degrees),there was statistical significant difference(t =-2.321 P = 0.025).The mean difference in the error of the Toric intraocular lens alignment measured by iTrace aberration and the slitlamp was(3.67±3.59) degrees(ranged 0-14 degrees).The results showed that there was less than 5 degrees of difference between the two methods in 32 eyes(71.1%),locate 5 to 10 degrees in 9 eyes(20%),more than 10 degrees in 4 eyes(8.9%).The correlation between the 2 methods showed significant linear relationship(r = 0.926 P 0.01).Conclusion Using iTrace aberration can accurately measure Toric intraocular lens alignment without mydriasis,the result has some reference value.
出处 《眼科新进展》 CAS 北大核心 2017年第2期161-163,共3页 Recent Advances in Ophthalmology
关键词 iTrace像差仪 TORIC人工晶状体 晶状体轴位 旋转 iTrace aberration Toric intraocular lens alignment rotation
  • 相关文献

参考文献2

二级参考文献26

  • 1王雁,赵堪兴.波前像差与临床视觉矫正[M].北京:人民卫生出版社,2011:41. 被引量:12
  • 2Amesbury EC, Miller KM. Correction of astigmatism at the time of cataract surgery [ J . Curt Opin Ophthalmol,2009,20 ( 1 ) : 19- 24. 被引量:1
  • 3Dardzhikova A, Shah CR, Gimbel HV. Early experience with the AcrySof toric IOL for the correction of astigmatism in cataract surgery [J]. Can J Ophthalmol,2009,44 ( 3 ) :259-273. 被引量:1
  • 4Tassignon M J, Gobin L, Mathysen D, Van Looveren J. Clinical re- sults after spherotoric intraocular lens implantation using the bag-in-the-lens technique [ J ]. J Cataract Refract Surg, 2011,37 (5) :830-834. 被引量:1
  • 5Entabi M ,Harman F,Lee N,Bloom PA. Injectable 1-piece hydro- philic acrylic toric intraocular lens for cataract surgery: Efficacy and stability E J]. J Cataract Refract Surg ,201'1,37 (2) :235-240. 被引量:1
  • 6Hoffmann PC, Auel S, Hiitz WW. Results of higher power toric intraocular lens implantation E J ]. J Cataract Refract Surg ,2011, 37(8) :1411-1418. 被引量:1
  • 7Kw J, Edwar-ds K. Evaluation of the long-term rotational sta- bility of single-piece, acrylic intraocular lenses [ J ]. Br J Oph- thalmol,2010,94 ( 8 ) : 1003-1006. 被引量:1
  • 8Visser N, Ruiz-Mesa R, Pastor F, Bauer N, Nuijts R, Monts-Mic6 R. Cataract surgery with toric intraocular lens implantation in patients with high corneal astigmatism [J]. J Cataract Refract Surg ,2011,37 ( 8 ) : 1403-1410. 被引量:1
  • 9Applegate RA, Hilmantel G, Howland HC, Tu EY, Starck T, Zayac EJ. Corneal first surface optical aberrations and visual performance[J]. J Refract Surt; ,2000,16(5) :507-514. 被引量:1
  • 10ArtaJ P , Berrio E, Guirao A, Piers P. Contribution of the cornea and internal surfaces to the change of ocular aberrations with age[J]. J Opt Soc Am A Opt Image Sci Vis ,2002 ,19 (1) : 137- 143. 被引量:1