摘要 某核电厂在调试期间,因凝汽器压力定值设置不合理触发凝汽器故障信号。从核电厂核岛、常规岛工艺、仪控专业全面分析了问题原因。利用传热学原理、凝汽器瞬态计算软件,进行了详细计算和风险判断,最终给出优化设计方案。解决方案有效提高了核电厂反应堆、汽轮机运行安全性和经济性。 During the commissioning of a certain nuclear power station, the condenser malfunction is activated due to unreasonable setting of the condenser pressure setpoint. The causes were fully analyzed from the aspects of nuclear/conventional island design as well as relevant I&C specialties. Based on the heat- transfer principle and required software, detailed calculation and risk judgment were carried out, and subsequently an optimal design scheme was proposed, which can effectively improve the operation safety and economic performance of relevant nuclear power reactors and steam turbines.
作者 黄美华 苏鸿
出处 《发电设备》 2017年第1期43-47,共5页 Power Equipment
关键词 凝汽器 故障 压力定值 优化设计 condenser malfunction pressure setpoint design optimization
  • 相关文献

参考文献6

二级参考文献21

  • 1李勇,曹祖庆.凝汽器清洁率的概念及测试方法[J].汽轮机技术,1995,37(2):73-76. 被引量:53
  • 2徐葆华.凝汽器传热系数计算方法分析[J].动力工程,1981,1(3):17-27. 被引量:2
  • 3杨善让.电站凝汽设备及运行管理[M].北京:水利电力出版社,1993.. 被引量:2
  • 4JG科利尔著 魏先英译.对流沸腾和凝结[M].北京:科学出版社,1982.. 被引量:2
  • 5McNell D A etc. An Experimental Study of Low-pressure Filmwise Condensation on A Small In-line Tube Bank [ J ]. Proc lnstn Mech Engrs ,2001,215 (A2) :231 - 243 被引量:1
  • 6Chisholm D. Modern Developments in Marine Condensers:Noncondensable Gases: An Overview. In Power Condenser Heat Transfer Technology[M] (Eds Marto P J and Nunn R H). Washington:Hemisphere Publishing Corporation 1981 被引量:1
  • 7胥传普.N125汽轮机及其热力系统全工况实时仿真数学模型[D].南京:东南大学,1986 被引量:1
  • 8[苏]B.П.勃留多夫等.汽轮机的凝汽设备[M].龚家彪等译.北京:水利电力出版社,1960 被引量:1
  • 9Beckett G. The Use of Computer Programs to Condenser Performance [J]. I. Chem. E. Symposium Series. 1983, No. 75:97 -110 被引量:1
  • 10田鹤年.用“气体状态系数法快速计算抽气器空气流量”中国电机工程学会大功率汽轮机组辅机学术年会论文集.1999.9. 被引量:1