以热泵机组提供5500kW/台热量,65℃高出水温度为需求,以热源侧为土壤,换热管中介质为水,换热后水温约10~15℃为条件,设计大型热泵机组,利用专业软件计算出制冷压缩机、冷凝器、节流阀、蒸发器和经济器等的选型结果,为大型热泵机组的批量生产提供设计依据。
Focused on providing 5500 kW heat and 65℃ water, using heat source as soil and water as a medium in heat exchange tube, based on the water temperature with 10-15℃ after heat exchange, this paper describes how to design large heat pump and how to guide the volume production of heat pump using professional software to choose proper model of compressor, condenser, throttle, evaporator and economizer.
出处
《建筑热能通风空调》
2016年第12期79-81,78,共4页
Building Energy & Environment
关键词
大型机组
热泵
高出水温度
large units
heat pump
high water temperature