期刊文献+

基于眼球生理结构和眼模型的眼底三维重建方法 被引量:1

3D reconstruction of fundus based on anatomical structure of eyeball and eye model
下载PDF
导出
摘要 为将眼底的各项生理结构和病灶信息在三维空间中显示出来,更好地辅助医生诊断,提出一种基于眼球生理结构和眼模型的眼底三维重建方法.首先通过分析眼底的生理结构和眼模型,将眼球后极部近似为局部球面;然后根据眼底相机参数以及视轴长度构建局部球面模型,把眼底图像恢复为三维结构;分割眼底图像中的血管和病灶部位,利用眼底三维模型,将血管和病灶部位显示在三维空间中.实验表明,平均每幅图像处理用时1.410 1 s,重建速度快、准确度高、可重复性高. In order to show the physiological structure and lesion information of fundus in 3D space to assist diagnose, a kind of new 3D reconstruction method of fundus based on the anatomical structure of eyeball and the eye model is proposed. Firstly, the posterior pole of eyeball is approximated as the partial sphere by analyzing the anatomical structure of eyeball and the eye model. Secondly, the partial sphere is calculated according to the fundus camera parameters and the axial length of eyeball, and the 3D model of fundus is reconstructed from the fundus image. Fi-nally, vessel and lesions of the fundus image is segmented and showed in the 3D space using the 3D model of fundus. The experimental results show that the average processing time of each image is 1.410 1 s, the proposed method has high reconstruction speed, high accuracy and high reproducibility.
出处 《天津工业大学学报》 CAS 北大核心 2016年第6期67-72,共6页 Journal of Tiangong University
基金 天津市科技支撑计划重点项目(13ZCZDGX02100) 天津市自然科学基金项目(15JCYBJC16600)
关键词 眼底图像 眼底三维重建 眼球生理结构 眼模型 局部球面模型 病灶信息 fundus image 3D reconstruction of fundus anatomical structure of eyeball eye model partial sphere model lesion information
  • 相关文献

参考文献8

二级参考文献77

  • 1李健,庞云阶.一种提取医疗图像中血管轮廓的简单方法[J].系统仿真学报,2001,13(S2):561-563. 被引量:2
  • 2李镜海,周芳,周树安,李树秋,刘石磷,巫洁.正常眼与近视眼多方位角膜厚度研究[J].中华眼科杂志,1994,30(6):445-448. 被引量:32
  • 3潘立丰,王利生.一种视网膜血管自适应提取方法[J].中国图象图形学报,2006,11(3):310-316. 被引量:8
  • 4Enrlque C, Sunanda M, Mark W, et al. Digital stereo image analyzer for generating automated 3-D measures of optic disc deformation in glaucoma. IEEE Transactions on Medical Imageing, 2002; 21(10) : 1244 被引量:1
  • 5Deguchl K, Kawamata D, Mizutani K, et al. 3D fundus shape reconstruction and display from stereo fundus images. IEICE Transactions on Information and Systems,2000; 83(7) : 1408 被引量:1
  • 6Doelemeyer A, Petting BL. Estimation of projection errors in human ocular fundus imaging. Ophthalmic Physiol Opt, 2000; 20(2) :112 被引量:1
  • 7于江波,陈后金.PCNN模型的改进及其在医学图像处理中的应用[J].电子与信息学报,2007,29(10):2316-2320. 被引量:8
  • 8Modis L Jr, Lanqenbucher A, Seitz B. Scanning-slit and spe- cular microscopic pachymetry in comparison with ultrasonic de- termination of corneal thickness[J]. Cornea, 2001,20(7):711-714. 被引量:1
  • 9Koktekir BE, Gedik S, Bakbak B. Comparison of central corneal thickness measurements with optical low-coherence reflectometry and ultrasound pachymetry and reproducibility of both devices[J]. Cornea, 2012,11(18) :677-678. 被引量:1
  • 10Spencer T, Olson JA, McHardy KC, et al. An image-processing strategy for the segmentation and quantification of microaneurysms in fluorescein angiograms of the ocular fundus [ J ]. Computers and Biomedical Research, 1996, 29(4) : 284 -302. 被引量:1

共引文献37

同被引文献4

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部