摘要 采用电磁场和电路联合仿真,基于直流测试和三维电磁建模仿真技术,建立了截止频率5 THz的混频肖特基二极管的等效电路模型。重点研究了二极管的非线性结模型和外围结构三维电磁全波仿真模型,构建了考虑实际电路形式的四端口三维电磁全波仿真模型。该等效电路模型可用于太赫兹低频段混频模块设计,该模型的建立方法也为更高频段模型的建立提供了一种参考。基于该模型设计了一款220 GHz分谐波混频器,在192~230 GHz宽带范围内,双边带变频损耗小于10 dB,测试结果与仿真结果较为一致。 An equivalent circuit model of mixing Schottky diode with cut-off frequency of 5 THz was reported based on DC measurement and 3-D electromagnetic (EM)simulation combined of EM simulator and circuit simulator. The model of nonlinear Schottky junction and 3-D periphery structure full-wave simulation model was researched carefully, the four-ports model considered real circuit topology was established. The equivalent circuit model can be used for design of mixers worked at the lower end of terahertz band, the methodology of this diode model was a reference of much more higher terahertz frequency. A sub-harmonic 220 GHz wideband mixer was designed based on the model, the double sideband conversion loss was less than 10 dB in the range of 192 GHz to 230 GHz, the measured result was well with the simulated result.
出处 《红外与激光工程》 EI CSCD 北大核心 2016年第9期248-252,共5页 Infrared and Laser Engineering
关键词 太赫兹 混频 肖特基二极管 模型 terahertz mixing Schottky diode model
  • 相关文献

参考文献3

二级参考文献20

  • 1MLLER R,HOEHL A.The metrology light source of PTB-a source for THz radiation[J].J.Infrared Milli. Terahertz Waves,2011, 32:742-753. 被引量:1
  • 2ZHANG X C.Introduction to THz Wave Photonics[M].New York: Rensselaer Polytechnic Institute,2009. 被引量:1
  • 3DIETLEIN C.Broadband THz aqueous blackbody calibration source [J].SPIE, 2007,6548:65480M-1-6. 被引量:1
  • 4STEIGER A,GUTSCHWAGER B.Optical methods for power measurement of terahertz radiation [J].Optics Express,2010,18(21):21804-21814. 被引量:1
  • 5WERNER L,HBERS H W.Towards traceable radiometry in the terahertz region [J].Metrologia,2009,46:160-164. 被引量:1
  • 6UTSCHWAGER B,MONTE C.Calculable blackbody radiation as a source for the determination of the spectral responsivity of THz detectors [J].Metrologia,2009,46:165-169. 被引量:1
  • 7LI H G,YANG H R.Study on detection and identification model of passive terahertz imaging system for extended target [J].SPIE,2010,7854: 785413-1-7. 被引量:1
  • 8LI H G.Study on terahertz radiation test of blackbody [J].SPIE,2012,8417:841730-1-6. 被引量:1
  • 9GUTSCHWAGER B,HOLLANDT J.A vacuum infrared standard radiation thermometer at the PTB [J].Int.J. Thermophys,2008,29:330-340. 被引量:1
  • 10LEE J W,SEO M A.Shape resonance terahertz filters [J].IEEE,2006,46:S165-S169. 被引量:1

共引文献22

同被引文献32

引证文献5

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部