微通道换热器铜铝管腐蚀失效分析及对策 被引量:1

Research on Cu-Al Pipe Corrosion Failure Analysis and Measures of Microchannel Heat Exchanger
下载PDF
导出
摘要 微通道换热器是制冷系统的重要组成部分,微通道的铜铝管腐蚀泄漏会导致制冷系统不起作用。本文针对微通道铜铝管的腐蚀失效样件,通过宏观、微观形貌分析、原材料化学成分测试、金相分析、红外光谱分析、XRD测试、扫描电镜及能谱分析,结合相关文献对铝管发生点腐蚀的原因及机理进行分析,并提出相应的预防措施。 Micro-channel heat exchanger is an important part of refrigeration system. The corrosion leakage of Cu-Al pipe in the micro-channel will lead to the operation failure of refrigeration system. Aiming at the corrosion failure samples of Cu-Al pipe in the micro-channel, and through the macroscopic and microcosmic feature analysis, chemi-cal composition analysis for raw material, metallographic analysis, infrared spectroscopic analysis, XRD test, scanning electron microscope, and energy spectrum analysis, and combined with the related documents for corrosion reasons of aluminium pipe and mechanism analysis, the relative precautionary measures are proposed.
出处 《日用电器》 2016年第7期33-37,共5页 ELECTRICAL APPLIANCES
关键词 微通道换热器 铝管 点腐蚀 氯离子 micro-channel heat exchanger aluminium pipe spot corrosion chloride ion
  • 相关文献

参考文献7

  • 1NuANG Z H CONWAY P P THOMSON R C. Microstructural C0nsiderat On far Ultratine Lead Free Solder Joints[J]. Microelecttonics Reliabil!ity, 2007,47( ! 2): 1997-2006. 被引量:1
  • 2王振波,尹鸽平,史鹏飞.铝电池用合金阳极的研究进展[J].电池,2003,33(1):41-43. 被引量:11
  • 3曹楚南编著..腐蚀电化学原理 第3版[M].北京:化学工业出版社,2008:268.
  • 4刘道新..材料的腐蚀与防护[M].西安:西北工业大学出版社,2010.
  • 5朱祖芳.有色金属的耐腐蚀性及其应用[M].北京:化学工业出版社,1998. 被引量:2
  • 6单毅敏,罗兵辉,柏振海.5083铝合金在3.5%NaCl溶液中的电化学腐蚀行为研究[J].铝加工,2007,30(1):11-14. 被引量:26
  • 7Buchheit R G,Morgan J P.Stoner G E.Electrochemical behavior of the T1 (Ai2CuLI ) intermetaillc compound and its role in localized corrosion Of Ai-2% LI-3%Cu alloys[J]. Corrosion; 1 994,50:120. 被引量:1

二级参考文献10

共引文献36

同被引文献28

引证文献1

二级引证文献5