摘要 基于弓网电弧模拟试验平台,分别利用可见光谱诊断方法对弓网电弧的辐射谱进行了初步研究,分析其特征谱线。由电弧辐射理论利用斜率法计算得出了电弧等离子体温度,并研究了不同运行状态下,弓网电弧等离子体的温度变化情况。结果表明:弓网电弧等离子体激发温度随着电流增大而增大,弓网间隙的增大也同样使温度增大。 The relationship between pantograph and catenary is one the of three key relationships of the safelyrunning high-speed railway,so it makes great sense in scientific research in theoretical and practical engineering.The radiation spectrums of pantograph-catenary arc were studied respectively, with the help of spectroscopy. Theradiation spectrums of arc plasma were collected by using spectrometer, its characteristic spectral lines were foundand the temperature of arc plasma was calculated through Bolezmann diagram method based on the theory of arcradiation. The changes of pantograph-catenary arc plasma temperature were studied under different running state.The results show that the temperature of pantograph-catenary arc is increasing with the increase of current and spacebetween pantograph and catenary.
出处 《电器与能效管理技术》 2016年第15期23-27,39,共6页 Electrical & Energy Management Technology
基金 国家自然科学基金重点项目(U1234202) 国家自然科学基金面上项目(51577158) 国家杰出青年科学基金(51325704)
关键词 弓网电弧 等离子体 可见光谱 Bolezmann作图法 pantograph-catenary arc plasmas spectroscopy Bolezmann plot
  • 相关文献

参考文献9

二级参考文献79

  • 1史宗谦,贾申利,王立军,王政.真空电弧电压与电弧形态关系的实验研究[J].高压电器,2004,40(4):250-252. 被引量:15
  • 2庄劲武,张晓锋,杨锋,王晨.一种新型直流电网短路限流装置的设计与分析[J].海军工程大学学报,2005,17(4):13-17. 被引量:22
  • 3秦襄培.Matlab图像处理与界面编程[M].北京:电子工业出版社,2009. 被引量:7
  • 4董华军,廖敏夫,邹积岩,邱红辉,周正阳.真空开关电弧图像采集及其处理过程[J].电工技术学报,2007,22(8):174-178. 被引量:20
  • 5BERNARDO T L, MASSIMO M, ROMANO G,et al. Line-pantograph EMI in railway systems [ J ]//IEEE Instrumentation & Measurement Magazine Volume:4, Issue,2001 (4) :10-13. 被引量:1
  • 6BUHRKALL L. DC components due to ice on the o- verhead contact wire of AC electrified railways [ J ]. Elektrische Bahnen, 2005 (8) :380-389. 被引量:1
  • 7SURAJIT M, DIERK B, THORSTEN S, et al. Panto- graph arcing in electrified railways-mechanism and in- fluence of various parameters [ J ]. IEEE Transactions of Power Delivery, 2009, 24(4) :1931-1938. 被引量:1
  • 8MIDYA S, SCH T, THOTTFAPPILLIL R. Conse- quences of DC components in AC railway and its elimi- nation, in Proceedings of Railway Engineering-2007 [J]. London: UK, Jun., 2007:1-12. 被引量:1
  • 9TELLINI M, MACUCCI R, GIANNETI'I G A. An- tonacci. Conducted and radiated interference measure- ments in the line-pantograph system [ J ]. IEEE Trans. Instrument Meas, 2001(50) :1661-200l. 被引量:1
  • 10LEVA S, MORANDO A P, ZICH R E. On the un- wanted radiated fields due to the sliding contacts in a traction system [ J ]. IEICE Trans. Commun. , 2000, E83-B:515-519. 被引量:1