钢管混凝土结构作为一种较为合理的结构形式,一般都有很好地经济性。为了在750 k V变电构架结构中大力推广钢管混凝土结构,同时为桥湾750 k V变电站提供设计依据,进行了750 k V钢管混凝土变电构架结构中3种关键节点的试验研究。试验结果表明:各类节点均具有较高的强度储备和延性,且破坏形态满足"强节点弱杆件"的设计原则,经依托工程实践总结后可在750 k V变电构架结构中推广应用。
As a reasonable structure in mechanical properties, the concrete filled steel tube (CFT) structure generally has considerable economic value. To promote construction of CFT structure in 750 kV substation, and provide theoretical basis for construction of the Qiaowan 750 kV substation in Gansu, experiment study on three kinds of key connection joints is performed. Test results show that all joints used in project have high strength reserve and ductility, and the failure form are all satisfied with 'strong connection and weak bar' design principle. It is can be widely applied in 750 kV CFT substation after summarization on engineering projects. This work is supported by the Ministry of Housing and Urban-Rural Development (MOHURD) project (No. 2014-K2-01 l), the Shaanxi Natural Science Foundation (No. 2014JM7244), the Special Research Foundation (No. 2013JK0977) from the Education Institution of Shaanxi, 2014 Research Project of the SGCC (State Grid Corpotation of China) Supporting Innovative Construction and Infrastructure Technologies.